Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
72
matching recommendationsNAICS | 33641 | Aerospace Product and Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0106 # 02 Y:2006 | 02 | 2006 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $43,630 | $20,000 | Not Implemented |
UU0106 # 01 Y:2006 | 01 | 2006 | OPTIMIZE PLANT POWER FACTOR | $19,900 | $40,020 | Not Implemented |
UU0086 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $773 | $4,320 | Not Implemented |
UU0086 # 01 Y:2005 | 01 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,056 | $12,620 | Not Implemented |
UU0086 # 02 Y:2005 | 02 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,984 | $6,400 | Not Implemented |
UU0086 # 03 Y:2005 | 03 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $17,445 | $3,600 | Not Implemented |
UU0086 # 04 Y:2005 | 04 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,447 | $21,000 | Not Implemented |
UU0086 # 06 Y:2005 | 06 | 2005 | OPTIMIZE PLANT POWER FACTOR | $15,260 | $14,000 | Not Implemented |
UU0060 # 07 Y:2004 | 07 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,897 | $200 | Implemented |
UU0060 # 06 Y:2004 | 06 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,853 | $0 | Not Implemented |
UU0060 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $309 | $723 | Not Implemented |
UU0060 # 04 Y:2004 | 04 | 2004 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $3,047 | $2,600 | Not Implemented |
UU0060 # 03 Y:2004 | 03 | 2004 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $5,059 | $4,000 | Implemented |
UU0060 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,695 | $4,800 | Not Implemented |
UU0060 # 01 Y:2004 | 01 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,202 | $13,200 | Implemented |
UU0051 # 01 Y:2003 | 01 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,232 | $0 | Not Implemented |
UU0051 # 07 Y:2003 | 07 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,270 | $8,450 | Not Implemented |
UU0051 # 06 Y:2003 | 06 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,510 | $5,980 | Not Implemented |
UU0051 # 05 Y:2003 | 05 | 2003 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,823 | $0 | Not Implemented |
UU0051 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,130 | $11,800 | Not Implemented |
UU0051 # 03 Y:2003 | 03 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,845 | $961 | Not Implemented |
UU0051 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $744 | $340 | Not Implemented |