Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
202
matching recommendationsSIC | 20 | Food and Kindred Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0475 # 08 Y:2000 | 08 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $130 | $0 | Implemented |
MA0471 # 01 Y:2000 | 01 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $7,546 | $18,500 | Not Implemented |
MA0471 # 02 Y:2000 | 02 | 2000 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $3,105 | $11,000 | Not Implemented |
MA0471 # 03 Y:2000 | 03 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,804 | $7,200 | Not Implemented |
MA0471 # 04 Y:2000 | 04 | 2000 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $1,548 | $4,000 | Not Implemented |
MA0471 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,361 | $19,740 | Not Implemented |
MA0471 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $114 | $120 | Implemented |
MA0468 # 01 Y:2000 | 01 | 2000 | USE OTHER METHODS FOR NEUTRALIZATION | $28,530 | $100,000 | Implemented |
MA0468 # 02 Y:2000 | 02 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $17,250 | $47,030 | Not Implemented |
MA0468 # 03 Y:2000 | 03 | 2000 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $390 | $440 | Implemented |
MA0468 # 04 Y:2000 | 04 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $304 | $474 | Implemented |
MA0445 # 01 Y:1999 | 01 | 1999 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $160,542 | $811,250 | Not Implemented |
MA0445 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $3,122 | $7,125 | Not Implemented |
MA0445 # 03 Y:1999 | 03 | 1999 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,546 | $472 | Implemented |
MA0445 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $353 | $1,090 | Implemented |
MA0323 # 01 Y:1995 | 01 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,470 | $4,000 | Not Implemented |
MA0323 # 02 Y:1995 | 02 | 1995 | USE RADIANT HEATER FOR SPOT HEATING | $1,300 | $2,820 | Not Implemented |
MA0323 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $685 | $500 | Implemented |
MA0323 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $346 | $511 | Not Implemented |
MA0315 # 01 Y:1994 | 01 | 1994 | BURN A LESS EXPENSIVE GRADE OF FUEL | $10,053 | $33,627 | Not Implemented |
MA0315 # 02 Y:1994 | 02 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,672 | $3,805 | Not Implemented |
MA0315 # 03 Y:1994 | 03 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,932 | $1,776 | Not Implemented |
MA0315 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,707 | $1,678 | Not Implemented |
MA0315 # 05 Y:1994 | 05 | 1994 | INSULATE BARE EQUIPMENT | $1,350 | $4,238 | Not Implemented |
MA0315 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $933 | $0 | Implemented |