Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsSIC | 2015 | Poultry Slaughtering And Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0827 # 10 Y:2006 | 10 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,887 | $3,400 | Implemented |
GT0827 # 09 Y:2006 | 09 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $158,948 | $150,000 | Implemented |
GT0827 # 08 Y:2006 | 08 | 2006 | METER WASTE WATER | $81,583 | $5,250 | Implemented |
GT0827 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,361 | $2,328 | Implemented |
GT0827 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,421 | $4,053 | Implemented |
GT0736 # 09 Y:2002 | 09 | 2002 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $8,580 | $0 | Implemented |
GT0736 # 06 Y:2002 | 06 | 2002 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $8,300 | $0 | Implemented |
GT0736 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $33,702 | $5,000 | Implemented |
GT0736 # 02 Y:2002 | 02 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $384 | $500 | Implemented |
GT0618 # 05 Y:1997 | 05 | 1997 | MINIMIZE WATER USAGE | $3,550 | $3,450 | Implemented |
GT0618 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,175 | $99,710 | Implemented |
GT0618 # 01 Y:1997 | 01 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $52,000 | $2,000 | Implemented |
GT0618 # 04 Y:1997 | 04 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $149,009 | $238,000 | Implemented |
GT0618 # 03 Y:1997 | 03 | 1997 | INSULATE BARE EQUIPMENT | $3,600 | $3,000 | Implemented |
GT0528 # 07 Y:1994 | 07 | 1994 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $42,800 | $45,000 | Implemented |
GT0528 # 05 Y:1994 | 05 | 1994 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $13,300 | $10,000 | Implemented |
GT0528 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $730 | $920 | Implemented |
GT0528 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,540 | $15,210 | Implemented |
GT0447 # 03 Y:1991 | 03 | 1991 | REPAIR AND ELIMINATE STEAM LEAKS | $754 | $150 | Implemented |
GT0447 # 05 Y:1991 | 05 | 1991 | HEAT WATER WITH EXHAUST HEAT | $60,730 | $125,000 | Implemented |
GT0447 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,147 | $5,838 | Implemented |
GT0447 # 02 Y:1991 | 02 | 1991 | INSULATE BARE EQUIPMENT | $534 | $1,330 | Implemented |
GT0447 # 01 Y:1991 | 01 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,880 | $500 | Implemented |
GT0392 # 05 Y:1989 | 05 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,680 | $2,110 | Implemented |
GT0392 # 06 Y:1989 | 06 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $3,490 | $375 | Implemented |