Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
276
matching recommendationsSIC | 202 | Dairy Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0307 # 01 Y:2002 | 01 | 2002 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $115,174 | $476,400 | Not Implemented |
SD0307 # 02 Y:2002 | 02 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,963 | $18,000 | Not Implemented |
SD0307 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $1,517 | $2,500 | Not Implemented |
SD0307 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $933 | $1,200 | Not Implemented |
SD0307 # 05 Y:2002 | 05 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $785 | $0 | Not Implemented |
SD0307 # 06 Y:2002 | 06 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,134 | $5,000 | Not Implemented |
SF0219 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,206 | $0 | Implemented |
SF0219 # 02 Y:2001 | 02 | 2001 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $5,816 | $5,705 | Implemented |
SF0219 # 03 Y:2001 | 03 | 2001 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $415 | $406 | Implemented |
SF0219 # 04 Y:2001 | 04 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $529 | $840 | Implemented |
SF0219 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,695 | $11,140 | Not Implemented |
SF0219 # 06 Y:2001 | 06 | 2001 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $14,216 | $507 | Implemented |
SF0217 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,715 | $0 | Implemented |
SF0217 # 02 Y:2001 | 02 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $611 | $0 | Implemented |
SF0217 # 03 Y:2001 | 03 | 2001 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $2,551 | $248 | Implemented |
SF0217 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,181 | $3,150 | Implemented |
SF0217 # 05 Y:2001 | 05 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,600 | $1,761 | Implemented |
SF0217 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $730 | $1,032 | Implemented |
SF0217 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,141 | $2,088 | Not Implemented |
SF0217 # 08 Y:2001 | 08 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,410 | $15,510 | Implemented |
SF0217 # 09 Y:2001 | 09 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,231 | $4,000 | Not Implemented |
SD0271 # 01 Y:2001 | 01 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $6,508 | $0 | Not Implemented |
SD0271 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,184 | $360 | Implemented |
SD0271 # 03 Y:2001 | 03 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,818 | $18,000 | Not Implemented |
SD0271 # 04 Y:2001 | 04 | 2001 | INSTALL SKYLIGHTS | $3,038 | $8,000 | Not Implemented |