Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
145
matching recommendationsSIC | 2023 | Dry, Condensed, Evaporated Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0023 # 07 Y:2008 | 07 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,600 | $8,310 | Implemented |
TT0023 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,275 | $4,900 | Implemented |
TT0023 # 09 Y:2008 | 09 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $1,750 | $1,600 | Implemented |
UF0414 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,527 | $7,379 | Implemented |
UF0414 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $44,500 | $13,000 | Implemented |
UF0414 # 04 Y:2008 | 04 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,808 | $15,562 | Implemented |
UF0414 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $255 | $39 | Implemented |
UF0414 # 06 Y:2008 | 06 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,447 | $371 | Implemented |
OR0507 # 01 Y:2006 | 01 | 2006 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,600 | $0 | Implemented |
OR0507 # 02 Y:2006 | 02 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $46,800 | $2,000 | Implemented |
OR0507 # 04 Y:2006 | 04 | 2006 | KEEP BOILER TUBES CLEAN | $13,700 | $4,000 | Implemented |
OR0507 # 05 Y:2006 | 05 | 2006 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $40,000 | $1,500 | Implemented |
OR0507 # 06 Y:2006 | 06 | 2006 | ADD ADDITIONAL PRODUCTION SHIFT | $60,100 | $41,100 | Implemented |
OR0507 # 10 Y:2006 | 10 | 2006 | INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE | $22,760 | $24,900 | Implemented |
OR0507 # 15 Y:2006 | 15 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,890 | $19,200 | Implemented |
SU0220 # 01 Y:2005 | 01 | 2005 | KEEP BOILER TUBES CLEAN | $17,434 | $0 | Implemented |
SU0220 # 03 Y:2005 | 03 | 2005 | USE SYNTHETIC LUBRICANT | $488 | $0 | Implemented |
SU0220 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $47,114 | $10,000 | Implemented |
SU0220 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,882 | $765 | Implemented |
SU0220 # 07 Y:2005 | 07 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $8,034 | $2,780 | Implemented |
SU0220 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,271 | $667 | Implemented |
SU0220 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $420 | $408 | Implemented |
OR0441 # 01 Y:2003 | 01 | 2003 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $65,260 | $70,100 | Implemented |
OR0441 # 02 Y:2003 | 02 | 2003 | SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE | $18,970 | $2,160 | Implemented |
OR0441 # 03 Y:2003 | 03 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,670 | $985 | Implemented |