Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
124
matching recommendationsSIC | 2032 | Canned Specialties |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0189 # 01 Y:2000 | 01 | 2000 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $8,181 | $8,239 | Implemented |
SF0189 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $807 | $1,711 | Implemented |
SF0189 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $1,491 | $2,520 | Implemented |
SF0189 # 05 Y:2000 | 05 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $8,916 | $14,480 | Implemented |
SF0189 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,102 | $36,670 | Implemented |
SF0189 # 07 Y:2000 | 07 | 2000 | MINIMIZE WATER USAGE | $23,452 | $125,000 | Implemented |
ME0241 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,669 | $38,422 | Implemented |
ME0241 # 03 Y:1998 | 03 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $14,710 | $12,260 | Implemented |
ME0241 # 04 Y:1998 | 04 | 1998 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $5,602 | $7,719 | Implemented |
ME0241 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,877 | $500 | Implemented |
ME0241 # 06 Y:1998 | 06 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $444 | $804 | Implemented |
ME0241 # 07 Y:1998 | 07 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $214 | $250 | Implemented |
UD0519 # 01 Y:1997 | 01 | 1997 | USE GRAVITY FEEDS WHEREVER POSSIBLE | $9,099 | $5,828 | Implemented |
UD0519 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $557 | $1,915 | Implemented |
UD0519 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $453 | $888 | Implemented |
UD0519 # 04 Y:1997 | 04 | 1997 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $811 | $0 | Implemented |
UD0519 # 05 Y:1997 | 05 | 1997 | INSTALL EQUIPMENT TO MOVE PRODUCT | $14,413 | $6,000 | Implemented |
OK0519 # 01 Y:1997 | 01 | 1997 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $178,301 | $18,000 | Implemented |
OK0519 # 02 Y:1997 | 02 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,853 | $15,000 | Implemented |
OK0519 # 03 Y:1997 | 03 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,927 | $0 | Implemented |
OK0519 # 04 Y:1997 | 04 | 1997 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $14,177 | $20,000 | Implemented |
OK0519 # 06 Y:1997 | 06 | 1997 | USE OTHER METHODS FOR NEUTRALIZATION | $11,000 | $50,000 | Implemented |
OK0519 # 07 Y:1997 | 07 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $467 | $880 | Implemented |
OK0519 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $115 | $644 | Implemented |
AS0053 # 04 Y:1992 | 04 | 1992 | INSULATE BARE EQUIPMENT | $12,327 | $5,772 | Implemented |