Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

747

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0205 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,579 $20,000 n/a
NC0205 # 03 Y:2000 03 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $15,232 $20,000 n/a
NC0205 # 04 Y:2000 04 2000 $11,092 $16,250 n/a
NC0205 # 05 Y:2000 05 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $10,548 $2,000 n/a
NC0205 # 06 Y:2000 06 2000 $15,300 $200 n/a
NC0200 # 01 Y:2000 01 2000 RECOVER WASTE HEAT FROM EQUIPMENT $20,439 $27,000 n/a
NC0200 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,705 $51,300 n/a
NC0200 # 03 Y:2000 03 2000 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $921 $1,000 n/a
NC0200 # 04 Y:2000 04 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $30,871 $10,600 n/a
NC0200 # 05 Y:2000 05 2000 METER WASTE WATER $15,526 $7,025 n/a
NC0190 # 01 Y:2000 01 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $16,521 $3,000 n/a
NC0190 # 02 Y:2000 02 2000 KEEP BOILER TUBES CLEAN $16,531 $15,000 n/a
NC0190 # 03 Y:2000 03 2000 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $163 $300 n/a
NC0190 # 04 Y:2000 04 2000 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $19,521 $8,000 n/a
NC0190 # 05 Y:2000 05 2000 DISCONNECT BALLASTS $2,180 $1,800 n/a
NC0190 # 06 Y:2000 06 2000 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $202,493 $450,000 n/a
NC0190 # 07 Y:2000 07 2000 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $76,945 $200,000 n/a
NC0177 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $434 $120 Implemented
NC0177 # 02 Y:1999 02 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,366 $2,141 Implemented
NC0177 # 03 Y:1999 03 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $8,265 $420 Not Implemented
NC0177 # 04 Y:1999 04 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $450 $500 Implemented
NC0177 # 05 Y:1999 05 1999 RECOVER AND REUSE COOLING WATER $97,444 $35,500 Implemented
NC0178 # 01 Y:1999 01 1999 MODIFY TEXTILE DRYERS $72,691 $1,000 Implemented
NC0178 # 02 Y:1999 02 1999 CHECK FOR ACCURACY OF UTILITY / POWER METERS $14,400 $5,600 Implemented
NC0178 # 03 Y:1999 03 1999 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $15,967 $6,000 Not Implemented