Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
154
matching recommendationsSIC | 221 | Broadwoven Fabric Mills, Cotton |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0434 # 10 Y:2003 | 10 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $965 | $800 | Implemented |
LM0058 # 04 Y:2003 | 04 | 2003 | INSULATE BARE EQUIPMENT | $6,265 | $2,028 | Implemented |
LM0058 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,174 | $250 | Implemented |
LM0058 # 01 Y:2003 | 01 | 2003 | ADD AREA LIGHTING SWITCHES | $6,786 | $7,274 | Implemented |
GT0705 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,420 | $0 | Implemented |
GT0705 # 03 Y:2000 | 03 | 2000 | MINIMIZE WATER USAGE | $1,457 | $300 | Implemented |
NC0135 # 06 Y:1998 | 06 | 1998 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $170,000 | $750,000 | Implemented |
OD0075 # 06 Y:1996 | 06 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,440 | $3,111 | Implemented |
OD0075 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,775 | $19,955 | Implemented |
OD0075 # 04 Y:1996 | 04 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $4,186 | $5,691 | Implemented |
OD0075 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,546 | $51,404 | Implemented |
OD0075 # 01 Y:1996 | 01 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $21,911 | $1,400 | Implemented |
GT0573 # 03 Y:1995 | 03 | 1995 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $1,950 | $6,270 | Implemented |
GT0519 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,860 | $14,260 | Implemented |
GT0519 # 05 Y:1994 | 05 | 1994 | INCREASE AMOUNT OF CONDENSATE RETURNED | $14,440 | $6,500 | Implemented |
GT0501 # 01 Y:1993 | 01 | 1993 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,620 | $10,000 | Implemented |
GT0501 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,930 | $115,900 | Implemented |
GT0501 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $21,500 | $3,500 | Implemented |
GT0501 # 06 Y:1993 | 06 | 1993 | UPGRADE CONTROLS ON COMPRESSORS | $21,170 | $30,000 | Implemented |
GT0501 # 07 Y:1993 | 07 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,710 | $65,530 | Implemented |
GT0503 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $780 | $450 | Implemented |
GT0503 # 04 Y:1993 | 04 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $8,700 | $3,090 | Implemented |
GT0502 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,020 | $1,280 | Implemented |
GT0502 # 01 Y:1993 | 01 | 1993 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $10,870 | $13,500 | Implemented |
GT0502 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,230 | $30,840 | Implemented |