Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsSIC | 221 | Broadwoven Fabric Mills, Cotton |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0493 # 13 Y:2013 | 13 | 2013 | CONDENSE OPERATION INTO ONE BUILDING | $21,473 | $10,000 | Implemented |
NC0493 # 09 Y:2013 | 09 | 2013 | REDUCE EXCESSIVE BOILER BLOWDOWN | $430 | $0 | Implemented |
NC0493 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,550 | $1,386 | Implemented |
NC0493 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,165 | $100 | Implemented |
NC0493 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,789 | $215,791 | Implemented |
NC0493 # 05 Y:2013 | 05 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,850 | $6,372 | Implemented |
NC0284 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,521 | $1,002 | Implemented |
NC0284 # 02 Y:2004 | 02 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,667 | $10,600 | Implemented |
NC0284 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,310 | $26,200 | Implemented |
NC0284 # 07 Y:2004 | 07 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $469 | $1,000 | Implemented |
NC0135 # 06 Y:1998 | 06 | 1998 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $170,000 | $750,000 | Implemented |
TN0369 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $280 | $0 | Implemented |
TN0369 # 03 Y:1989 | 03 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $1,909 | $240 | Implemented |
TN0369 # 04 Y:1989 | 04 | 1989 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $2,350 | $3,325 | Implemented |
TN0369 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $11,956 | $0 | Implemented |
TN0369 # 10 Y:1989 | 10 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,943 | $450 | Implemented |
TN0369 # 09 Y:1989 | 09 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $147 | $50 | Implemented |
TN0369 # 08 Y:1989 | 08 | 1989 | CLOSE OFF UNNEEDED STEAM LINES | $845 | $0 | Implemented |
AT0093 # 01 Y:1988 | 01 | 1988 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $124,949 | $261,000 | Implemented |
AT0093 # 02 Y:1988 | 02 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $770 | $130 | Implemented |
AT0093 # 03 Y:1988 | 03 | 1988 | INSULATE BARE EQUIPMENT | $281 | $200 | Implemented |
AT0093 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $419 | $746 | Implemented |
AT0093 # 06 Y:1988 | 06 | 1988 | IMPROVE LUBRICATION PRACTICES | $1,829 | $0 | Implemented |
AT0093 # 07 Y:1988 | 07 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $884 | $0 | Implemented |
AT0093 # 08 Y:1988 | 08 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $336 | $150 | Implemented |