Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
386
matching recommendationsSIC | 221 | Broadwoven Fabric Mills, Cotton |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0201 # 03 Y:2000 | 03 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $56,972 | $10,000 | Not Implemented |
NC0201 # 04 Y:2000 | 04 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $24,065 | $105,600 | Not Implemented |
NC0201 # 05 Y:2000 | 05 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $5,960 | $2,500 | Not Implemented |
NC0205 # 01 Y:2000 | 01 | 2000 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $6,613 | $1,000 | n/a |
NC0205 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,579 | $20,000 | n/a |
NC0205 # 03 Y:2000 | 03 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $15,232 | $20,000 | n/a |
NC0205 # 04 Y:2000 | 04 | 2000 | ELIMINATE SHUTDOWNS OF CONTROLS DUE TO OVERHEATING | $11,092 | $16,250 | n/a |
NC0205 # 05 Y:2000 | 05 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,548 | $2,000 | n/a |
NC0205 # 06 Y:2000 | 06 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $15,300 | $200 | n/a |
NC0190 # 01 Y:2000 | 01 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $16,521 | $3,000 | n/a |
NC0190 # 02 Y:2000 | 02 | 2000 | KEEP BOILER TUBES CLEAN | $16,531 | $15,000 | n/a |
NC0190 # 03 Y:2000 | 03 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $163 | $300 | n/a |
NC0190 # 04 Y:2000 | 04 | 2000 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $19,521 | $8,000 | n/a |
NC0190 # 05 Y:2000 | 05 | 2000 | DISCONNECT BALLASTS | $2,180 | $1,800 | n/a |
NC0190 # 06 Y:2000 | 06 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $202,493 | $450,000 | n/a |
NC0190 # 07 Y:2000 | 07 | 2000 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $76,945 | $200,000 | n/a |
NC0135 # 01 Y:1998 | 01 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,630 | $0 | Not Implemented |
NC0135 # 02 Y:1998 | 02 | 1998 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $10,801 | $5,400 | Not Implemented |
NC0135 # 03 Y:1998 | 03 | 1998 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $2,079 | $7,200 | Not Implemented |
NC0135 # 04 Y:1998 | 04 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $16,897 | $5,200 | Not Implemented |
NC0135 # 05 Y:1998 | 05 | 1998 | MINIMIZE WATER USAGE | $16,515 | $15,000 | Not Implemented |
NC0135 # 06 Y:1998 | 06 | 1998 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $170,000 | $750,000 | Implemented |
NC0135 # 07 Y:1998 | 07 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $600,450 | $1,500,000 | Not Implemented |
OD0085 # 04 Y:1997 | 04 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,962 | $1,495 | n/a |
OD0085 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,532 | $3,048 | n/a |