Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

386

matching recommendations
Reset
SIC 221 Broadwoven Fabric Mills, Cotton
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0201 # 03 Y:2000 03 2000 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $56,972 $10,000 Not Implemented
NC0201 # 04 Y:2000 04 2000 UPGRADE CONTROLS ON COMPRESSORS $24,065 $105,600 Not Implemented
NC0201 # 05 Y:2000 05 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $5,960 $2,500 Not Implemented
NC0205 # 01 Y:2000 01 2000 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $6,613 $1,000 n/a
NC0205 # 02 Y:2000 02 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,579 $20,000 n/a
NC0205 # 03 Y:2000 03 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $15,232 $20,000 n/a
NC0205 # 04 Y:2000 04 2000 ELIMINATE SHUTDOWNS OF CONTROLS DUE TO OVERHEATING $11,092 $16,250 n/a
NC0205 # 05 Y:2000 05 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $10,548 $2,000 n/a
NC0205 # 06 Y:2000 06 2000 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $15,300 $200 n/a
NC0190 # 01 Y:2000 01 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $16,521 $3,000 n/a
NC0190 # 02 Y:2000 02 2000 KEEP BOILER TUBES CLEAN $16,531 $15,000 n/a
NC0190 # 03 Y:2000 03 2000 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $163 $300 n/a
NC0190 # 04 Y:2000 04 2000 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $19,521 $8,000 n/a
NC0190 # 05 Y:2000 05 2000 DISCONNECT BALLASTS $2,180 $1,800 n/a
NC0190 # 06 Y:2000 06 2000 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $202,493 $450,000 n/a
NC0190 # 07 Y:2000 07 2000 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $76,945 $200,000 n/a
NC0135 # 01 Y:1998 01 1998 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,630 $0 Not Implemented
NC0135 # 02 Y:1998 02 1998 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $10,801 $5,400 Not Implemented
NC0135 # 03 Y:1998 03 1998 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,079 $7,200 Not Implemented
NC0135 # 04 Y:1998 04 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $16,897 $5,200 Not Implemented
NC0135 # 05 Y:1998 05 1998 MINIMIZE WATER USAGE $16,515 $15,000 Not Implemented
NC0135 # 06 Y:1998 06 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $170,000 $750,000 Implemented
NC0135 # 07 Y:1998 07 1998 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $600,450 $1,500,000 Not Implemented
OD0085 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,962 $1,495 n/a
OD0085 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,532 $3,048 n/a