Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 2426 | Hardwood Dimension & Flooring Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0215 # 03 Y:2019 | 03 | 2019 | REPAIR OR REPLACE STEAM TRAPS | $15,764 | $1,150 | Implemented |
TT0189 # 05 Y:2017 | 05 | 2017 | INSULATE BARE EQUIPMENT | $864 | $2,140 | Implemented |
TT0189 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,767 | $4,837 | Implemented |
TT0189 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,177 | $3,050 | Implemented |
TT0037 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,750 | $2,900 | Implemented |
TT0032 # 07 Y:2009 | 07 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,170 | $2,500 | Implemented |
TN0691 # 08 Y:2000 | 08 | 2000 | USE RE-USABLE FILTERS | $640 | $0 | Implemented |
TN0560 # 09 Y:1995 | 09 | 1995 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $16,400 | $27,400 | Implemented |
TN0560 # 02 Y:1995 | 02 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,066 | $0 | Implemented |
TN0502 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,039 | $750 | Implemented |
TN0502 # 05 Y:1993 | 05 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,204 | $0 | Implemented |
TN0392 # 11 Y:1990 | 11 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $952 | $490 | Implemented |
TN0392 # 10 Y:1990 | 10 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,859 | $760 | Implemented |
TN0392 # 07 Y:1990 | 07 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,374 | $1,000 | Implemented |
TN0392 # 06 Y:1990 | 06 | 1990 | ADJUST VENTS TO MINIMIZE ENERGY USE | $10,842 | $4,670 | Implemented |
TN0392 # 05 Y:1990 | 05 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $524 | $2,000 | Implemented |
TN0392 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $12,329 | $0 | Implemented |
TN0392 # 03 Y:1990 | 03 | 1990 | REPAIR AND ELIMINATE STEAM LEAKS | $2,222 | $4,000 | Implemented |
TN0392 # 02 Y:1990 | 02 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,052 | $9,401 | Implemented |
TN0378 # 04 Y:1989 | 04 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $2,083 | $540 | Implemented |
TN0378 # 08 Y:1989 | 08 | 1989 | INSTALL SET-BACK TIMERS | $1,524 | $0 | Implemented |
TN0378 # 07 Y:1989 | 07 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,301 | $120 | Implemented |
TN0378 # 05 Y:1989 | 05 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,802 | $7,500 | Implemented |