IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

521

matching recommendations
Reset
SIC 2426 Hardwood Dimension & Flooring Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0680 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,356 $18,370 Not Implemented
TN0680 # 05 Y:2000 05 2000 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $2,810 $500 Implemented
TN0680 # 06 Y:2000 06 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $960 $0 Not Implemented
MO0267 # 01 Y:1999 01 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,983 $4,472 Implemented
MO0267 # 02 Y:1999 02 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $436 $0 Implemented
MO0267 # 03 Y:1999 03 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $2,700 $0 Implemented
MO0267 # 04 Y:1999 04 1999 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $0 $0 Implemented
MO0267 # 05 Y:1999 05 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $24,480 $0 Not Implemented
MO0267 # 06 Y:1999 06 1999 $38,556 $5,053 Not Implemented
NC0166 # 01 Y:1999 01 1999 RECOVER WASTE HEAT FROM EQUIPMENT $756 $1,500 Implemented
NC0166 # 02 Y:1999 02 1999 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $5,877 $15,000 Not Implemented
NC0166 # 03 Y:1999 03 1999 USE PHOTOCELL CONTROLS $601 $150 Implemented
NC0166 # 04 Y:1999 04 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,328 $5,000 Not Implemented
NC0166 # 05 Y:1999 05 1999 INSULATE FEEDWATER TANK $328 $340 Implemented
NC0166 # 06 Y:1999 06 1999 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $645 $800 Not Implemented
NC0166 # 07 Y:1999 07 1999 BURN WOOD BY-PRODUCTS FOR HEAT $12,902 $62,200 Not Implemented
NC0166 # 08 Y:1999 08 1999 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $29,365 $82,000 Not Implemented
NC0166 # 09 Y:1999 09 1999 $14,000 $15,500 Implemented
NC0166 # 10 Y:1999 10 1999 $7,700 $1,000 Implemented
ME0239 # 01 Y:1998 01 1998 REPAIR AND ELIMINATE STEAM LEAKS $46,878 $873 Implemented
ME0239 # 02 Y:1998 02 1998 $10,701 $0 Implemented
ME0239 # 03 Y:1998 03 1998 $4,685 $32,332 Not Implemented
ME0239 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,290 $19,457 Not Implemented
ME0239 # 05 Y:1998 05 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $2,074 $239 Implemented
ME0239 # 06 Y:1998 06 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,534 $1,671 Not Implemented