Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,511
matching recommendationsSIC | 243 | Millwork, Plywood & Structural |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0533 # 01 Y:2008 | 01 | 2008 | REDUCE SCRAP PRODUCTION | $34,537 | $0 | Implemented |
OR0533 # 02 Y:2008 | 02 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $19,500 | $157,850 | Not Implemented |
OR0533 # 03 Y:2008 | 03 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,560 | $3,680 | Not Implemented |
OR0533 # 04 Y:2008 | 04 | 2008 | INSTALL OCCUPANCY SENSORS | $7,000 | $44,710 | Not Implemented |
OR0533 # 05 Y:2008 | 05 | 2008 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $8,300 | $2,500 | Implemented |
OR0533 # 06 Y:2008 | 06 | 2008 | OPTIMIZE PLANT POWER FACTOR | $3,400 | $5,075 | Not Implemented |
WV0381 # 01 Y:2008 | 01 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $70,581 | $24,000 | Not Implemented |
WV0381 # 02 Y:2008 | 02 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $43,659 | $3,500 | Not Implemented |
WV0381 # 03 Y:2008 | 03 | 2008 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $53,901 | $12,000 | Not Implemented |
WV0381 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,296 | $19,992 | Implemented |
WV0381 # 05 Y:2008 | 05 | 2008 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $28,475 | $76,200 | Implemented |
WV0381 # 06 Y:2008 | 06 | 2008 | OPTIMIZE PLANT POWER FACTOR | $25,696 | $34,550 | Implemented |
WV0381 # 07 Y:2008 | 07 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $25,395 | $2,100 | Implemented |
WV0381 # 08 Y:2008 | 08 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $21,259 | $25,425 | Implemented |
WV0381 # 09 Y:2008 | 09 | 2008 | COMBINE UTILITY METERS | $10,426 | $20,000 | Not Implemented |
WV0381 # 10 Y:2008 | 10 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $8,516 | $1,250 | Not Implemented |
WV0381 # 11 Y:2008 | 11 | 2008 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $7,681 | $10,660 | Implemented |
WV0381 # 12 Y:2008 | 12 | 2008 | INSTALL SET-BACK TIMERS | $6,981 | $1,150 | Implemented |
WV0381 # 13 Y:2008 | 13 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,036 | $38,700 | Not Implemented |
WV0381 # 14 Y:2008 | 14 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,586 | $0 | Not Implemented |
WV0381 # 15 Y:2008 | 15 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,545 | $2,940 | Not Implemented |
WV0381 # 16 Y:2008 | 16 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,867 | $1,300 | Not Implemented |
CO0612 # 01 Y:2008 | 01 | 2008 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $13,590 | $59,400 | Not Implemented |
CO0612 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,920 | $300 | Implemented |
CO0612 # 03 Y:2008 | 03 | 2008 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $160 | $450 | Implemented |