Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

45

matching recommendations
Reset
SIC 251 Household Furniture
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0186 # 05 Y:2017 05 2017 UPGRADE CONTROLS ON COMPRESSORS $12,015 $33,000 Implemented
TT0186 # 02 Y:2017 02 2017 UPGRADE CONTROLS ON COMPRESSORS $78,651 $90,000 Implemented
TT0186 # 03 Y:2017 03 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $44,574 $5,800 Implemented
TT0108 # 04 Y:2013 04 2013 REPAIR AND ELIMINATE STEAM LEAKS $4,000 $980 Implemented
TT0108 # 01 Y:2013 01 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,126 $10,709 Implemented
MZ0102 # 01 Y:2012 01 2012 INSTALL OCCUPANCY SENSORS $930 $700 Implemented
MZ0102 # 03 Y:2012 03 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,327 $2,000 Implemented
MZ0102 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,326 $16,800 Implemented
MZ0102 # 06 Y:2012 06 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,370 $2,270 Implemented
MZ0102 # 04 Y:2012 04 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,444 $0 Implemented
TN0621 # 08 Y:1997 08 1997 MAINTAIN MACHINES TO REDUCE LEAKS $1,980 $2,780 Implemented
TN0621 # 02 Y:1997 02 1997 $17,500 $17,900 Implemented
TN0530 # 10 Y:1994 10 1994 MAKE A NEW BY-PRODUCT $100,000 $988,447 Implemented
TN0530 # 05 Y:1994 05 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $4,015 $0 Implemented
TN0479 # 02 Y:1993 02 1993 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $418 $720 Implemented
TN0399 # 04 Y:1990 04 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,844 $900 Implemented
TN0399 # 06 Y:1990 06 1990 INSTALL TIMERS AND/OR THERMOSTATS $1,873 $185 Implemented
TN0399 # 07 Y:1990 07 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $416 $96 Implemented
TN0399 # 08 Y:1990 08 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $813 $680 Implemented
TN0399 # 09 Y:1990 09 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $583 $210 Implemented
TN0399 # 03 Y:1990 03 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $825 $687 Implemented
TN0399 # 01 Y:1990 01 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,222 $2,750 Implemented
TN0355 # 08 Y:1988 08 1988 IMPROVE LUBRICATION PRACTICES $1,071 $0 Implemented
TN0355 # 07 Y:1988 07 1988 DISCONNECT BALLASTS $1,320 $2,321 Implemented
TN0355 # 06 Y:1988 06 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,943 $1,220 Implemented