Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,622
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0147 # 06 Y:2014 | 06 | 2014 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,184 | $600 | Implemented |
MZ0147 # 09 Y:2014 | 09 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,212 | $420 | Implemented |
MZ0147 # 10 Y:2014 | 10 | 2014 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $3,158 | $250 | Implemented |
SU0363 # 01 Y:2014 | 01 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $8,835 | $0 | Implemented |
SU0363 # 02 Y:2014 | 02 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,805 | $0 | Implemented |
SU0363 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $419 | $40 | Implemented |
SU0363 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $942 | $156 | Implemented |
SU0363 # 05 Y:2014 | 05 | 2014 | INSTALL OCCUPANCY SENSORS | $245 | $101 | Implemented |
SU0363 # 06 Y:2014 | 06 | 2014 | ELIMINATE/REDUCE AN OPERATION | $2,875 | $3,456 | Implemented |
SU0363 # 07 Y:2014 | 07 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $293 | $732 | Implemented |
SU0363 # 08 Y:2014 | 08 | 2014 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $263 | $810 | Implemented |
SU0363 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $682 | $3,264 | Implemented |
MA0727 # 03 Y:2014 | 03 | 2014 | PAY UTILITY BILLS ON TIME | $6,481 | $500 | Implemented |
MA0727 # 05 Y:2014 | 05 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,122 | $1,500 | Implemented |
WM0042 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,231 | $300 | Implemented |
WM0042 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,162 | $9,680 | Implemented |
WM0042 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $322 | $340 | Implemented |
MA0725 # 01 Y:2014 | 01 | 2014 | BURN A LESS EXPENSIVE GRADE OF FUEL | $1,049,475 | $2,750,000 | Implemented |
MA0725 # 05 Y:2014 | 05 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $28,833 | $9,690 | Implemented |
MA0725 # 06 Y:2014 | 06 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $23,788 | $9,000 | Implemented |
MA0725 # 08 Y:2014 | 08 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,977 | $12,270 | Implemented |
MA0725 # 10 Y:2014 | 10 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,314 | $10,600 | Implemented |
MA0725 # 12 Y:2014 | 12 | 2014 | INSULATE BARE EQUIPMENT | $3,366 | $30,760 | Implemented |
SU0355 # 03 Y:2014 | 03 | 2014 | INSULATE FEEDWATER TANK | $267 | $52 | Implemented |
SU0355 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,150 | $1,655 | Implemented |