Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,617

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0376 # 07 Y:1992 07 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,699 $0 Implemented
KU0376 # 11 Y:1992 11 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,686 $30,000 Implemented
KU0376 # 14 Y:1992 14 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,826 $3,200 Implemented
KU0376 # 15 Y:1992 15 1992 REPAIR AND ELIMINATE STEAM LEAKS $1,201 $120 Implemented
WI0144 # 03 Y:1992 03 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,538 $3,314 Implemented
WI0144 # 04 Y:1992 04 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $309 $0 Implemented
WI0144 # 09 Y:1992 09 1992 INSTALL TIMERS AND/OR THERMOSTATS $957 $200 Implemented
WI0144 # 10 Y:1992 10 1992 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $423 $0 Implemented
RU0139 # 01 Y:1992 01 1992 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $10,985 $201 Implemented
RU0139 # 02 Y:1992 02 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,401 $68 Implemented
RU0139 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,050 $2,523 Implemented
RU0139 # 04 Y:1992 04 1992 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,165 $2,500 Implemented
RU0139 # 05 Y:1992 05 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $921 $500 Implemented
RU0139 # 06 Y:1992 06 1992 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $14,070 $0 Implemented
RU0142 # 05 Y:1992 05 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $222 $0 Implemented
WI0139 # 06 Y:1992 06 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,205 $5,344 Implemented
WI0139 # 14 Y:1992 14 1992 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $913 $650 Implemented
HO0011 # 01 Y:1992 01 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,962 $5,609 Implemented
HO0011 # 02 Y:1992 02 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,300 $4,500 Implemented
HO0011 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,264 $14,884 Implemented
ND0015 # 01 Y:1991 01 1991 REDUCE VENTILATION AIR $1,838 $750 Implemented
ND0015 # 02 Y:1991 02 1991 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,700 $250 Implemented
ND0015 # 03 Y:1991 03 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $225 $453 Implemented
ND0015 # 04 Y:1991 04 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $470 $200 Implemented
ND0015 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11 $0 Implemented