Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
45
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0073 # 09 Y:1996 | 09 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $7,618 | $2,100 | Implemented |
DS0073 # 08 Y:1996 | 08 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,117 | $300 | Implemented |
DS0073 # 07 Y:1996 | 07 | 1996 | REPAIR AND ELIMINATE STEAM LEAKS | $19,400 | $1,600 | Implemented |
DS0073 # 06 Y:1996 | 06 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,061 | $380 | Implemented |
DS0073 # 04 Y:1996 | 04 | 1996 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,106 | $0 | Implemented |
DS0073 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,223 | $6,467 | Implemented |
DS0073 # 02 Y:1996 | 02 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,263 | $340 | Implemented |
MS0070 # 04 Y:1996 | 04 | 1996 | DISCONNECT BALLASTS | $2,838 | $40 | Implemented |
MS0070 # 03 Y:1996 | 03 | 1996 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $2,600 | $120 | Implemented |
MS0070 # 05 Y:1996 | 05 | 1996 | REDUCE SCRAP PRODUCTION | $39,200 | $2,000 | Implemented |
ND0257 # 06 Y:1996 | 06 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,584 | $725 | Implemented |
ND0257 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $164 | $1,344 | Implemented |
ND0257 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $750 | Implemented |
WI0278 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $5,933 | $1,000 | Implemented |
WI0278 # 09 Y:1996 | 09 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $546 | $0 | Implemented |
WI0278 # 13 Y:1996 | 13 | 1996 | MINIMIZE WATER USAGE | $1,424 | $0 | Implemented |
WI0278 # 02 Y:1996 | 02 | 1996 | INSTALL SET-BACK TIMERS | $15,919 | $2,400 | Implemented |
WI0278 # 03 Y:1996 | 03 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $11,230 | $500 | Implemented |
WI0278 # 12 Y:1996 | 12 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,899 | $740 | Implemented |
WI0278 # 11 Y:1996 | 11 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,999 | $10,000 | Implemented |
WI0278 # 07 Y:1996 | 07 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,818 | $0 | Implemented |
WI0277 # 08 Y:1996 | 08 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,453 | $500 | Implemented |
WI0277 # 04 Y:1996 | 04 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,365 | $9,500 | Implemented |
UF0158 # 09 Y:1996 | 09 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,074 | $2,000 | Implemented |
UF0158 # 08 Y:1996 | 08 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $22,535 | $24,000 | Implemented |