Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,112
matching recommendationsSIC | 267 | Misc. Converted Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0251 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,870 | $10,160 | n/a |
BD0251 # 08 Y:2004 | 08 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,779 | $2,000 | Not Implemented |
BD0251 # 09 Y:2004 | 09 | 2004 | USE SYNTHETIC LUBRICANT | $2,224 | $1,200 | Not Implemented |
BD0251 # 10 Y:2004 | 10 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,106 | $3,570 | Not Implemented |
BD0251 # 11 Y:2004 | 11 | 2004 | INSTALL OCCUPANCY SENSORS | $1,202 | $2,670 | Not Implemented |
BD0251 # 12 Y:2004 | 12 | 2004 | INSTALL OCCUPANCY SENSORS | $1,199 | $2,100 | Not Implemented |
BD0251 # 13 Y:2004 | 13 | 2004 | USE PHOTOCELL CONTROLS | $767 | $650 | Not Implemented |
BD0251 # 14 Y:2004 | 14 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $52,949 | $8,000 | Not Implemented |
MA0542 # 01 Y:2003 | 01 | 2003 | OPTIMIZE PLANT POWER FACTOR | $14,636 | $22,869 | Not Implemented |
MA0542 # 02 Y:2003 | 02 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,600 | $21,400 | Not Implemented |
MA0542 # 03 Y:2003 | 03 | 2003 | REDUCE VENTILATION AIR | $9,202 | $3,400 | Not Implemented |
MA0542 # 04 Y:2003 | 04 | 2003 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $8,465 | $0 | Implemented |
MA0542 # 05 Y:2003 | 05 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,383 | $0 | Implemented |
MA0542 # 06 Y:2003 | 06 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,232 | $500 | Implemented |
MA0542 # 07 Y:2003 | 07 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,659 | $3,400 | Not Implemented |
MA0536 # 01 Y:2003 | 01 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $112,689 | $118,000 | Implemented |
MA0536 # 02 Y:2003 | 02 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $91,341 | $30,000 | Implemented |
MA0536 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $64,338 | $60,000 | Implemented |
MA0536 # 04 Y:2003 | 04 | 2003 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $69,333 | $5,900 | Implemented |
MA0536 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,935 | $22,000 | n/a |
MA0536 # 06 Y:2003 | 06 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,568 | $8,480 | Not Implemented |
MA0536 # 07 Y:2003 | 07 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,205 | $11,500 | n/a |
MA0536 # 08 Y:2003 | 08 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,766 | $11,500 | n/a |
MA0536 # 09 Y:2003 | 09 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,484 | $11,500 | n/a |
MA0536 # 10 Y:2003 | 10 | 2003 | INSULATE BARE EQUIPMENT | $5,400 | $2,600 | Implemented |