Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

622

matching recommendations
Reset
SIC 2671 Paper Coated & Laminated, Packaging
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0168 # 04 Y:1996 04 1996 OPTIMIZE PLANT POWER FACTOR $2,820 $7,774 Not Implemented
UL0168 # 05 Y:1996 05 1996 INSTALL TIMERS AND/OR THERMOSTATS $459 $200 Not Implemented
UL0168 # 06 Y:1996 06 1996 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $265 $265 Not Implemented
UL0168 # 07 Y:1996 07 1996 REGENERATE CLEANING SOLVENT ON-SITE AND REUSE $17,338 $3,000 Not Implemented
UL0168 # 08 Y:1996 08 1996 USE EVAPORATION TO CONCENTRATE MATERIAL $16,800 $5,070 Implemented
AS0169 # 01 Y:1996 01 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,089 $0 Not Implemented
AS0169 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,086 $9,303 Not Implemented
AS0169 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,012 $2,346 Not Implemented
AS0169 # 04 Y:1996 04 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,505 $3,920 Not Implemented
AS0169 # 05 Y:1996 05 1996 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,630 $0 Not Implemented
AS0169 # 06 Y:1996 06 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $13,920 $19,750 Not Implemented
AS0169 # 07 Y:1996 07 1996 MINIMIZE WATER USAGE $4,951 $3,000 Not Implemented
IA0131 # 01 Y:1995 01 1995 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $33,809 $11,700 Not Implemented
IA0131 # 02 Y:1995 02 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $21,688 $64,875 Implemented
IA0131 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,393 $9,302 Implemented
IA0131 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,757 $390 Implemented
IA0131 # 05 Y:1995 05 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,181 $25 Implemented
IA0131 # 06 Y:1995 06 1995 DIRECT WARMEST AIR TO COMBUSTION INTAKE $167 $360 Not Implemented
AR0059 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,115 $554 Implemented
AR0059 # 02 Y:1995 02 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $13,187 $3,130 Implemented
AR0059 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,258 $3,820 Implemented
AR0059 # 04 Y:1995 04 1995 OPTIMIZE PLANT POWER FACTOR $2,940 $7,020 Not Implemented
AR0059 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $623 $0 Implemented
AR0059 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,288 $200 Implemented
AR0059 # 07 Y:1995 07 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $996 $300 Implemented