Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

311

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0438 # 04 Y:2011 04 2011 REPAIR OR REPLACE STEAM TRAPS $19,936 $5,500 Not Implemented
NC0438 # 03 Y:2011 03 2011 REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT $19,068 $32,000 Not Implemented
NC0438 # 02 Y:2011 02 2011 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $8,972 $7,800 Implemented
NC0438 # 01 Y:2011 01 2011 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $62,448 $94,000 Not Implemented
NC0405 # 04 Y:2010 04 2010 TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS $31,421 $0 Not Implemented
NC0405 # 03 Y:2010 03 2010 DEVELOP A REPAIR/REPLACE POLICY $1,096 $4,858 Not Implemented
NC0405 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $900 $100 Implemented
NC0405 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $227 $200 Implemented
NC0391 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,946 $59,958 Not Implemented
NC0391 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $257 $100 Implemented
NC0391 # 04 Y:2009 04 2009 DEVELOP A REPAIR/REPLACE POLICY $4,320 $6,886 Not Implemented
NC0391 # 03 Y:2009 03 2009 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $5,889 $6,500 Not Implemented
NC0391 # 02 Y:2009 02 2009 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $18,020 $25,000 Implemented
NC0391 # 01 Y:2009 01 2009 INCREASE AMOUNT OF CONDENSATE RETURNED $5,716 $10,000 Implemented
NC0382 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,264 $4,408 Implemented
NC0382 # 06 Y:2008 06 2008 DEVELOP A REPAIR/REPLACE POLICY $1,644 $2,483 Implemented
NC0382 # 05 Y:2008 05 2008 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,226 $0 Implemented
NC0382 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,333 $100 Implemented
NC0382 # 03 Y:2008 03 2008 RECOVER WASTE HEAT FROM EQUIPMENT $11,864 $6,150 Not Implemented
NC0382 # 02 Y:2008 02 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,305 $8,000 Not Implemented
NC0382 # 01 Y:2008 01 2008 Alternate Fuel $1,350 $1,000 Implemented
NC0370 # 06 Y:2007 06 2007 MINIMIZE WATER USAGE $74,891 $121,780 Not Implemented
NC0370 # 01 Y:2007 01 2007 ADJUST BURNERS FOR EFFICIENT OPERATION $30,975 $65,000 Not Implemented
NC0370 # 02 Y:2007 02 2007 REPAIR OR REPLACE STEAM TRAPS $43,809 $17,100 Not Implemented
NC0370 # 03 Y:2007 03 2007 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $48,420 $25,000 Not Implemented