Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
489
matching recommendationsSIC | 2834 | Pharmaceutical Preparations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0252 # 05 Y:2000 | 05 | 2000 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,167 | $10,200 | Implemented |
SD0252 # 06 Y:2000 | 06 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,692 | $1,500 | Implemented |
SD0252 # 07 Y:2000 | 07 | 2000 | INSTALL SKYLIGHTS | $70,269 | $5,536 | Implemented |
SF0179 # 01 Y:1999 | 01 | 1999 | INSTALL OCCUPANCY SENSORS | $276 | $480 | Implemented |
SF0179 # 03 Y:1999 | 03 | 1999 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $564 | $2,476 | Implemented |
SF0179 # 04 Y:1999 | 04 | 1999 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $1,350 | $150 | Implemented |
SF0179 # 05 Y:1999 | 05 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $600 | $150 | Implemented |
SF0179 # 06 Y:1999 | 06 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $312 | $150 | Implemented |
SF0179 # 08 Y:1999 | 08 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $7,000 | $838 | Implemented |
SF0179 # 09 Y:1999 | 09 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $26,208 | $33,300 | Implemented |
OK0577 # 01 Y:1999 | 01 | 1999 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $28,907 | $0 | Implemented |
OK0577 # 04 Y:1999 | 04 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,556 | $117 | Implemented |
OK0577 # 07 Y:1999 | 07 | 1999 | INSULATE BARE EQUIPMENT | $784 | $3,820 | Implemented |
CO0422 # 01 Y:1998 | 01 | 1998 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $5,830 | $0 | Implemented |
CO0422 # 03 Y:1998 | 03 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $880 | $2,000 | Implemented |
CO0422 # 04 Y:1998 | 04 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $560 | $0 | Implemented |
CO0422 # 07 Y:1998 | 07 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $400 | $130 | Implemented |
CO0422 # 08 Y:1998 | 08 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $158,670 | $50,000 | Implemented |
CO0422 # 09 Y:1998 | 09 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $9,500 | $0 | Implemented |
NC0133 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,797 | $7,696 | Implemented |
NC0133 # 02 Y:1998 | 02 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,905 | $1,400 | Implemented |
NC0133 # 04 Y:1998 | 04 | 1998 | RECOVER AND REUSE COOLING WATER | $97,026 | $2,000 | Implemented |
NC0133 # 06 Y:1998 | 06 | 1998 | ADD ADDITIONAL PRODUCTION SHIFT | $500,800 | $0 | Implemented |
IA0183 # 01 Y:1997 | 01 | 1997 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $6,078 | $68,000 | Implemented |
IA0183 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,353 | $3,856 | Implemented |