Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

40

matching recommendations
Reset
SIC 2851 Paints And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0405 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $900 $100 Implemented
NC0405 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $227 $200 Implemented
NC0382 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,264 $4,408 Implemented
NC0382 # 06 Y:2008 06 2008 DEVELOP A REPAIR/REPLACE POLICY $1,644 $2,483 Implemented
NC0382 # 05 Y:2008 05 2008 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,226 $0 Implemented
NC0382 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,333 $100 Implemented
NC0382 # 01 Y:2008 01 2008 Alternate Fuel $1,350 $1,000 Implemented
NC0361 # 06 Y:2007 06 2007 ADJUST BURNERS FOR EFFICIENT OPERATION $1,849 $1,200 Implemented
NC0361 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,209 $1,540 Implemented
NC0361 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,791 $1,674 Implemented
NC0361 # 04 Y:2007 04 2007 DEVELOP A REPAIR/REPLACE POLICY $658 $617 Implemented
NC0361 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $579 $100 Implemented
NC0361 # 07 Y:2007 07 2007 ADJUST BURNERS FOR EFFICIENT OPERATION $1,150 $1,200 Implemented
NC0361 # 08 Y:2007 08 2007 ADJUST BURNERS FOR EFFICIENT OPERATION $452 $500 Implemented
NC0211 # 06 Y:2001 06 2001 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,631 $0 Implemented
NC0211 # 04 Y:2001 04 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,453 $6,000 Implemented
NC0211 # 03 Y:2001 03 2001 USE MINIMUM STEAM OPERATING PRESSURE $2,014 $250 Implemented
NC0211 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,719 $800 Implemented
NC0211 # 01 Y:2001 01 2001 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $23,426 $20,000 Implemented
NC0085 # 07 Y:1996 07 1996 USE LESS WASTEFUL PACKAGING $437 $0 Implemented
NC0085 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $910 $520 Implemented
NC0085 # 03 Y:1996 03 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $738 $600 Implemented
AT0032 # 01 Y:1985 01 1985 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,538 $3,544 Implemented
AT0032 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,391 $300 Implemented
AT0032 # 03 Y:1985 03 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $8,375 $3,000 Implemented