Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
428
matching recommendationsSIC | 286 | Industrial Organic Chemicals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0773 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $201 | $1,887 | Implemented |
OK0773 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $81 | $425 | Implemented |
TT0033 # 02 Y:2009 | 02 | 2009 | REPAIR OR REPLACE STEAM TRAPS | $78,500 | $40,000 | Implemented |
TT0033 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,616 | $2,500 | Implemented |
TT0033 # 07 Y:2009 | 07 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,200 | $0 | Implemented |
TT0033 # 08 Y:2009 | 08 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $24,600 | $27,800 | Implemented |
OR0540 # 01 Y:2008 | 01 | 2008 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $29 | $10,000 | Implemented |
OR0540 # 02 Y:2008 | 02 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $14,149 | $6,100 | Implemented |
OR0540 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $2,932 | $13,049 | Implemented |
WV0383 # 03 Y:2008 | 03 | 2008 | REPLACE BOILER | $4,983 | $9,450 | Implemented |
WV0383 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,268 | $260 | Implemented |
WV0383 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $1,008 | $375 | Implemented |
WV0383 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $742 | $1,995 | Implemented |
WV0383 # 11 Y:2008 | 11 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $655 | $0 | Implemented |
WV0383 # 12 Y:2008 | 12 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $380 | $800 | Implemented |
NC0383 # 01 Y:2008 | 01 | 2008 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $16,582 | $1,000 | Implemented |
NC0383 # 02 Y:2008 | 02 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $38,474 | $0 | Implemented |
NC0383 # 03 Y:2008 | 03 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $42,558 | $50,000 | Implemented |
NC0383 # 05 Y:2008 | 05 | 2008 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $4,551 | $10,000 | Implemented |
NC0383 # 09 Y:2008 | 09 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,623 | $100 | Implemented |
NC0383 # 10 Y:2008 | 10 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $11,700 | $11,589 | Implemented |
NC0383 # 11 Y:2008 | 11 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,695 | $1,497 | Implemented |
WV0382 # 01 Y:2008 | 01 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $165,919 | $5,500 | Implemented |
WV0382 # 02 Y:2008 | 02 | 2008 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $109,212 | $38,900 | Implemented |
WV0382 # 06 Y:2008 | 06 | 2008 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,768 | $3,213 | Implemented |