Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
389
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0320 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $451 | $455 | Implemented |
ND0320 # 07 Y:1999 | 07 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $100 | $153 | Not Implemented |
ND0320 # 08 Y:1999 | 08 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,251 | $1,600 | Not Implemented |
ND0320 # 09 Y:1999 | 09 | 1999 | PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW | $969 | $1,376 | Not Implemented |
ND0320 # 10 Y:1999 | 10 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,428 | $125 | Not Implemented |
UM0135 # 01 Y:1999 | 01 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,898 | $20,000 | Implemented |
UM0135 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $453 | $1,250 | Not Implemented |
UM0135 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,690 | $50 | Implemented |
UM0135 # 04 Y:1999 | 04 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,660 | $2,500 | Implemented |
UM0135 # 05 Y:1999 | 05 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $986 | $1,500 | Implemented |
UM0135 # 06 Y:1999 | 06 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $735 | $100 | Implemented |
ND0309 # 01 Y:1998 | 01 | 1998 | COMBINE UTILITY METERS | $12,379 | $24,759 | Not Implemented |
ND0309 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,616 | $17,376 | Implemented |
ND0309 # 03 Y:1998 | 03 | 1998 | RECOVER AND REUSE WASTE MATERIAL | $3,750 | $125 | Not Implemented |
ND0309 # 04 Y:1998 | 04 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $1,604 | $2,500 | Not Implemented |
ND0309 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,366 | $1,000 | Not Implemented |
ND0309 # 06 Y:1998 | 06 | 1998 | CONVERT TO AQUEOUS CLEANING SYSTEM | $848 | $100 | Implemented |
ND0309 # 07 Y:1998 | 07 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $478 | $0 | Implemented |
ND0309 # 08 Y:1998 | 08 | 1998 | INSTALL OCCUPANCY SENSORS | $458 | $800 | Not Implemented |
ND0309 # 09 Y:1998 | 09 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $131 | $60 | Implemented |
ND0309 # 10 Y:1998 | 10 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $101 | $250 | Not Implemented |
ND0309 # 11 Y:1998 | 11 | 1998 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $20 | $20 | Implemented |
UM0098 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $364 | $5,910 | Implemented |
UM0098 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,225 | $10,986 | Not Implemented |
UM0098 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $939 | $480 | Implemented |