Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

242

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0339 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,369 $50 Implemented
NC0320 # 01 Y:2005 01 2005 INSTALL COMMON HEADER ON COMPRESSORS $7,563 $100 Implemented
NC0320 # 02 Y:2005 02 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $9,200 $100 Not Implemented
NC0320 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,402 $50 Implemented
NC0320 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $193 $421 Implemented
NC0320 # 05 Y:2005 05 2005 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,900 $1,500 Not Implemented
NC0320 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $873 $100 Implemented
NC0320 # 07 Y:2005 07 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $902 $2,000 Implemented
NC0320 # 08 Y:2005 08 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $264 $25 Implemented
NC0316 # 01 Y:2005 01 2005 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $18,271 $87,125 Not Implemented
NC0316 # 02 Y:2005 02 2005 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $10,570 $26,949 Not Implemented
NC0316 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $491 $321 Not Implemented
NC0316 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $327 $100 Implemented
WV0312 # 01 Y:2005 01 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,023 $6,435 Not Implemented
WV0312 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,049 $18,750 Implemented
WV0312 # 03 Y:2005 03 2005 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $14,013 $9,600 Not Implemented
WV0312 # 04 Y:2005 04 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,107 $2,970 Implemented
WV0312 # 05 Y:2005 05 2005 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $5,641 $7,480 Not Implemented
WV0312 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,708 $250 Implemented
WV0312 # 07 Y:2005 07 2005 DEVELOP A REPAIR/REPLACE POLICY $3,672 $413 Not Implemented
WV0312 # 08 Y:2005 08 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,210 $4,800 Implemented
WV0312 # 09 Y:2005 09 2005 INSTALL OCCUPANCY SENSORS $1,797 $2,788 Implemented
WV0312 # 10 Y:2005 10 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,712 $824 Not Implemented
WV0312 # 11 Y:2005 11 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,460 $0 Implemented
WV0312 # 12 Y:2005 12 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $706 $120 Implemented