Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
760
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0248 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,847 | $4,555 | Implemented |
BD0248 # 15 Y:2003 | 15 | 2003 | $28,938 | $3,000 | Implemented | |
BD0248 # 02 Y:2003 | 02 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,672 | $24,600 | n/a |
BD0248 # 04 Y:2003 | 04 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $4,072 | $5,000 | Implemented |
BD0248 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,140 | $23,175 | Implemented |
TA0065 # 02 Y:2003 | 02 | 2003 | $64,800 | $5,200 | Implemented | |
TA0065 # 05 Y:2003 | 05 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,900 | $0 | Implemented |
TA0065 # 01 Y:2003 | 01 | 2003 | REDESIGN PROCESS | $75,086 | $0 | Implemented |
TA0065 # 10 Y:2003 | 10 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $194 | $0 | Not Implemented |
TA0065 # 08 Y:2003 | 08 | 2003 | MOVE BOILER TO MORE EFFICIENT LOCATION | $1,422 | $1,894 | Implemented |
TA0065 # 11 Y:2003 | 11 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $146 | $142 | Not Implemented |
TA0065 # 03 Y:2003 | 03 | 2003 | USE "WASH-LESS" PROCESSING EQUIPMENT | $49,000 | $1,768 | Not Implemented |
TA0065 # 04 Y:2003 | 04 | 2003 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $37,440 | $1,027 | Not Implemented |
TA0065 # 06 Y:2003 | 06 | 2003 | $2,426 | $6,000 | Implemented | |
TA0065 # 07 Y:2003 | 07 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,793 | $0 | Implemented |
TA0065 # 09 Y:2003 | 09 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $306 | $140 | Implemented |
WI0456 # 06 Y:2003 | 06 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,657 | $1,000 | Not Implemented |
WI0456 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,517 | $1,605 | Not Implemented |
WI0456 # 04 Y:2003 | 04 | 2003 | $5,139 | $1,240 | Not Implemented | |
WI0456 # 03 Y:2003 | 03 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $8,675 | $2,014 | Not Implemented |
WI0456 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,687 | $27,555 | Not Implemented |
WI0456 # 01 Y:2003 | 01 | 2003 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $20,554 | $25,000 | Not Implemented |
UF0334 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,397 | $57,060 | Implemented |
NC0269 # 02 Y:2003 | 02 | 2003 | INSULATE BARE EQUIPMENT | $16,965 | $5,128 | Implemented |
NC0269 # 01 Y:2003 | 01 | 2003 | $272,200 | $118,250 | Implemented |