Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
231
matching recommendationsSIC | 3061 | Mechanical Rubber Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0438 # 04 Y:2003 | 04 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,901 | $1,000 | Implemented |
WI0438 # 05 Y:2003 | 05 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,793 | $2,800 | Implemented |
WI0438 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $353 | $120 | Implemented |
UM0224 # 03 Y:2003 | 03 | 2003 | OPTIMIZE PLANT POWER FACTOR | $21,643 | $15,930 | Implemented |
UM0224 # 04 Y:2003 | 04 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $51,840 | $5,520 | Implemented |
UM0224 # 05 Y:2003 | 05 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $26,100 | $7,230 | Implemented |
UM0224 # 07 Y:2003 | 07 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,606 | $934 | Implemented |
UM0224 # 09 Y:2003 | 09 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,650 | $120 | Implemented |
UM0224 # 12 Y:2003 | 12 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $31,000 | $2,500 | Implemented |
SF0245 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,576 | $4,115 | Implemented |
SF0245 # 04 Y:2002 | 04 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,585 | $20,725 | Implemented |
SF0245 # 06 Y:2002 | 06 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,738 | $6,972 | Implemented |
SF0245 # 07 Y:2002 | 07 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,193 | $0 | Implemented |
HO0238 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $702 | $60 | Implemented |
HO0238 # 04 Y:2000 | 04 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,736 | $1,200 | Implemented |
HO0238 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,502 | $600 | Implemented |
HO0238 # 06 Y:2000 | 06 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $840 | $200 | Implemented |
HO0238 # 07 Y:2000 | 07 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $840 | $250 | Implemented |
HO0238 # 08 Y:2000 | 08 | 2000 | MOVE PRODUCT USING MECHANICAL MEANS | $1,220 | $40 | Implemented |
IA0233 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $139 | $45 | Implemented |
IA0233 # 05 Y:1999 | 05 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,757 | $2,000 | Implemented |
SD0234 # 04 Y:1999 | 04 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,069 | $1,425 | Implemented |
MA0436 # 02 Y:1999 | 02 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,170 | $27,774 | Implemented |
MA0436 # 03 Y:1999 | 03 | 1999 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $7,745 | $12,435 | Implemented |
MA0436 # 06 Y:1999 | 06 | 1999 | INSTALL OCCUPANCY SENSORS | $148 | $77 | Implemented |