Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
941
matching recommendationsSIC | 3086 | Plastics Foam Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0209 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $886 | $2,140 | Implemented |
LE0209 # 09 Y:2005 | 09 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $842 | $148 | Implemented |
LE0206 # 01 Y:2005 | 01 | 2005 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $135,669 | $50,000 | Not Implemented |
LE0206 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,193 | $5,000 | Implemented |
LE0206 # 03 Y:2005 | 03 | 2005 | INSTALL BACK-UP EQUIPMENT | $11,880 | $14,100 | Implemented |
LE0206 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,905 | $2,500 | Not Implemented |
LE0206 # 05 Y:2005 | 05 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,894 | $2,200 | Not Implemented |
LE0206 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $683 | $200 | Implemented |
LE0206 # 07 Y:2005 | 07 | 2005 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $63,361 | $382,500 | Not Implemented |
MI0098 # 01 Y:2005 | 01 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $24,731 | $1,000 | Implemented |
MI0098 # 02 Y:2005 | 02 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $7,463 | $111 | Implemented |
MI0098 # 03 Y:2005 | 03 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,950 | $1,910 | Implemented |
MI0098 # 04 Y:2005 | 04 | 2005 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,754 | $4,360 | Not Implemented |
MI0098 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $901 | $380 | Implemented |
MI0098 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $301 | $400 | Implemented |
MA0550 # 01 Y:2004 | 01 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $86,929 | $32,965 | Not Implemented |
MA0550 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,960 | $23,000 | Not Implemented |
MA0550 # 03 Y:2004 | 03 | 2004 | OPTIMIZE PLANT POWER FACTOR | $10,668 | $2,066 | Not Implemented |
MA0550 # 04 Y:2004 | 04 | 2004 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $599 | $0 | Not Implemented |
MA0550 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $547 | $0 | Not Implemented |
MA0550 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $185 | $120 | Not Implemented |
NC0253 # 01 Y:2003 | 01 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $81,956 | $105,000 | n/a |
NC0253 # 02 Y:2003 | 02 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,127 | $1,000 | Not Implemented |
NC0253 # 03 Y:2003 | 03 | 2003 | AVOID REWINDING MOTORS MORE THAN TWICE | $694 | $432 | Not Implemented |
NC0253 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $130 | $48 | Not Implemented |