Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
236
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0647 # 03 Y:1999 | 03 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $21,000 | $16,000 | Not Implemented |
TN0647 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,040 | $500 | Not Implemented |
TN0647 # 05 Y:1999 | 05 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $530 | $0 | Implemented |
TN0612 # 01 Y:1997 | 01 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $65,520 | $36,000 | Not Implemented |
TN0612 # 02 Y:1997 | 02 | 1997 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,210 | $0 | Not Implemented |
TN0612 # 03 Y:1997 | 03 | 1997 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $2,004 | $0 | Implemented |
TN0612 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,990 | $0 | Not Implemented |
TN0612 # 05 Y:1997 | 05 | 1997 | METER WASTE WATER | $660 | $235 | Not Implemented |
TN0612 # 06 Y:1997 | 06 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $600 | $220 | Implemented |
TN0612 # 07 Y:1997 | 07 | 1997 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $250 | $650 | Not Implemented |
TN0569 # 01 Y:1996 | 01 | 1996 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $18,480 | $0 | Not Implemented |
TN0569 # 02 Y:1996 | 02 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $3,578 | $4,440 | Not Implemented |
TN0569 # 03 Y:1996 | 03 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,833 | $17,762 | Not Implemented |
TN0569 # 04 Y:1996 | 04 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,428 | $4,000 | Not Implemented |
TN0569 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $318 | $30 | Implemented |
TN0526 # 01 Y:1994 | 01 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,380 | $4,530 | Not Implemented |
TN0526 # 02 Y:1994 | 02 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,322 | $2,040 | Not Implemented |
TN0526 # 03 Y:1994 | 03 | 1994 | INSULATE BARE EQUIPMENT | $8,137 | $770 | Not Implemented |
TN0526 # 04 Y:1994 | 04 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $4,066 | $3,700 | Not Implemented |
TN0526 # 05 Y:1994 | 05 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,280 | $0 | Implemented |
TN0526 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,398 | $1,250 | Implemented |
TN0526 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $950 | $1,656 | Implemented |
TN0517 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,223 | $8,688 | Implemented |
TN0517 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,213 | $1,080 | Implemented |
TN0517 # 03 Y:1994 | 03 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $668 | $0 | Not Implemented |