Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,651
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0747 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,358 | $41,789 | Implemented |
GT0747 # 07 Y:2003 | 07 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,662 | $1,500 | Implemented |
AM0428 # 01 Y:2003 | 01 | 2003 | $13,600 | $4,000 | Implemented | |
AM0428 # 03 Y:2003 | 03 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,020 | $0 | Implemented |
AM0424 # 01 Y:2003 | 01 | 2003 | USE ALTERNATIVE FLOCCULENT TO MINIMIZE SLUDGE VOLUME | $111,100 | $8,000 | Implemented |
AM0424 # 02 Y:2003 | 02 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $55,000 | $730 | Implemented |
AM0424 # 03 Y:2003 | 03 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $23,000 | $11,000 | Implemented |
AM0424 # 04 Y:2003 | 04 | 2003 | KEEP BOILER TUBES CLEAN | $5,720 | $500 | Implemented |
AM0424 # 06 Y:2003 | 06 | 2003 | USE SYNTHETIC LUBRICANT | $1,970 | $0 | Implemented |
AM0424 # 07 Y:2003 | 07 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,520 | $860 | Implemented |
AM0424 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $800 | $200 | Implemented |
AS0338 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $395 | $1,422 | Implemented |
AS0338 # 05 Y:2002 | 05 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $875 | $2,400 | Implemented |
AS0339 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $286 | $314 | Implemented |
AS0339 # 04 Y:2002 | 04 | 2002 | $113,273 | $9,000 | Implemented | |
MS0219 # 03 Y:2002 | 03 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $67,886 | $1,950 | Implemented |
MS0219 # 05 Y:2002 | 05 | 2002 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $23,617 | $1,500 | Implemented |
MS0219 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $20,902 | $97 | Implemented |
MS0219 # 07 Y:2002 | 07 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,779 | $1,113 | Implemented |
MS0219 # 08 Y:2002 | 08 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,971 | $696 | Implemented |
WI0433 # 01 Y:2002 | 01 | 2002 | CONVERT FROM BATCH OPERATION TO CONTINUOUS PROCESSING | $14,150 | $13,000 | Implemented |
WI0433 # 02 Y:2002 | 02 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,467 | $20,000 | Implemented |
WI0433 # 04 Y:2002 | 04 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,251 | $1,100 | Implemented |
WI0433 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $1,228 | $4,000 | Implemented |
WI0433 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $519 | $740 | Implemented |