Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
93
matching recommendationsSIC | 327 | Concrete, Gypsum, And Plaster Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0664 # 01 Y:2014 | 01 | 2014 | OPTIMIZE PLANT POWER FACTOR | $46,500 | $51,870 | Not Implemented |
AM0664 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $625 | $870 | Implemented |
AM0664 # 06 Y:2014 | 06 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,970 | $4,550 | Implemented |
AM0664 # 05 Y:2014 | 05 | 2014 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $5,260 | $0 | Implemented |
AM0664 # 04 Y:2014 | 04 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $7,770 | $1,200 | Implemented |
AM0664 # 03 Y:2014 | 03 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,750 | $12 | Not Implemented |
AM0664 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,030 | $3,600 | Implemented |
TA0080 # 04 Y:2004 | 04 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $3,990 | $1,600 | Implemented |
TA0080 # 01 Y:2004 | 01 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $67,776 | $13,000 | Implemented |
TA0080 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,160 | $585 | Implemented |
TA0080 # 03 Y:2004 | 03 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $7,900 | $875 | Implemented |
TA0080 # 05 Y:2004 | 05 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,000 | $1,000 | Implemented |
AM0428 # 01 Y:2003 | 01 | 2003 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $13,600 | $4,000 | Implemented |
AM0428 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,180 | $500 | Not Implemented |
AM0428 # 03 Y:2003 | 03 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,020 | $0 | Implemented |
TA0040 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $110 | $130 | Not Implemented |
TA0040 # 04 Y:2002 | 04 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,210 | $0 | Not Implemented |
TA0040 # 03 Y:2002 | 03 | 2002 | INCREASE EFFICIENCY OF TRUCKS | $2,552 | $0 | Implemented |
TA0040 # 02 Y:2002 | 02 | 2002 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,952 | $0 | Implemented |
TA0040 # 01 Y:2002 | 01 | 2002 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $11,200 | $12,425 | Implemented |
TA0040 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $181 | $90 | Not Implemented |
TA0040 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $140 | $0 | Not Implemented |
AM0344 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $610 | $0 | Implemented |
AM0344 # 05 Y:1999 | 05 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,150 | $140 | Implemented |
AM0344 # 04 Y:1999 | 04 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $21,800 | $0 | Implemented |