Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
86
matching recommendationsSIC | 329 | Misc. Nonmetallic Mineral Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0727 # 04 Y:2002 | 04 | 2002 | REDESIGN PROCESS | $2,159,550 | $0 | Implemented |
GT0727 # 06 Y:2002 | 06 | 2002 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $679,000 | $250,000 | Not Implemented |
GT0727 # 07 Y:2002 | 07 | 2002 | INSULATE BARE EQUIPMENT | $147,500 | $181,000 | Not Implemented |
GT0727 # 08 Y:2002 | 08 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $29,468 | $321,854 | Implemented |
GT0662 # 07 Y:1999 | 07 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,775 | $0 | Not Implemented |
GT0662 # 06 Y:1999 | 06 | 1999 | RECOVER AND REUSE COOLING WATER | $85,620 | $30,000 | Implemented |
GT0662 # 05 Y:1999 | 05 | 1999 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $68,343 | $60,000 | Implemented |
GT0662 # 08 Y:1999 | 08 | 1999 | COMBINE UTILITY METERS | $14,794 | $0 | Not Implemented |
GT0662 # 04 Y:1999 | 04 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $16,138 | $30,000 | Not Implemented |
GT0662 # 03 Y:1999 | 03 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $424,479 | $250,000 | Implemented |
GT0662 # 02 Y:1999 | 02 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $22,317 | $550 | Implemented |
GT0662 # 01 Y:1999 | 01 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,196 | $3,800 | Implemented |
GT0562 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $67,980 | $0 | Implemented |
GT0562 # 01 Y:1995 | 01 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $82,460 | $0 | Implemented |
GT0561 # 03 Y:1995 | 03 | 1995 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $99,420 | $0 | Not Implemented |
GT0561 # 01 Y:1995 | 01 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $473,300 | $1,050,000 | Implemented |
GT0561 # 02 Y:1995 | 02 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $166,370 | $235,000 | Not Implemented |
GT0561 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,950 | $4,550 | Implemented |
GT0561 # 05 Y:1995 | 05 | 1995 | USE SCREENING, MAGNETIC SEPARATION TO REMOVE CONTAMINANTS | $349,805 | $1,000,000 | Not Implemented |
GT0561 # 06 Y:1995 | 06 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,730 | $201,600 | Implemented |
GT0468 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,495 | $84,190 | Implemented |
GT0468 # 02 Y:1992 | 02 | 1992 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,368 | $3,500 | Implemented |
GT0468 # 03 Y:1992 | 03 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $17,240 | $0 | Implemented |
GT0461 # 09 Y:1992 | 09 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,673 | $3,500 | Implemented |
GT0461 # 01 Y:1992 | 01 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,414 | $300 | Implemented |