Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

154

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0230 # 08 Y:2003 08 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $233 $602 Not Implemented
MS0194 # 01 Y:2001 01 2001 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $110,856 $4,050 Not Implemented
MS0194 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $75,156 $10,000 n/a
MS0194 # 03 Y:2001 03 2001 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $26,678 $32,890 n/a
MS0194 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,507 $28,607 n/a
MS0194 # 05 Y:2001 05 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,241 $2,240 Not Implemented
MS0194 # 06 Y:2001 06 2001 INSTALL TIMERS AND/OR THERMOSTATS $856 $355 Not Implemented
MS0194 # 07 Y:2001 07 2001 DISCONNECT BALLASTS $824 $1,560 Not Implemented
MS0194 # 08 Y:2001 08 2001 INSTALL TIMERS AND/OR THERMOSTATS $536 $355 Not Implemented
MS0194 # 09 Y:2001 09 2001 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $2,041,680 $1,000,000 n/a
MS0194 # 10 Y:2001 10 2001 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $120,000 $96,000 n/a
MS0195 # 01 Y:2001 01 2001 RECOVER WASTE HEAT FROM EQUIPMENT $5,968 $1,701 Not Implemented
MS0195 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,494 $1,000 Implemented
MS0195 # 03 Y:2001 03 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,150 $7,965 Not Implemented
MS0195 # 04 Y:2001 04 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,088 $51 Not Implemented
MS0195 # 05 Y:2001 05 2001 INSTALL TIMERS AND/OR THERMOSTATS $74 $119 Implemented
MS0191 # 01 Y:2001 01 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $35,695 $1,000 Implemented
MS0191 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,525 $1,000 Implemented
MS0191 # 03 Y:2001 03 2001 PREHEAT COMBUSTION AIR WITH WASTE HEAT $67,125 $17,280 Not Implemented
MS0191 # 04 Y:2001 04 2001 PREHEAT COMBUSTION AIR WITH WASTE HEAT $14,314 $5,040 Not Implemented
MS0191 # 05 Y:2001 05 2001 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $5,216 $7,600 Not Implemented
MS0191 # 06 Y:2001 06 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,218 $367 Not Implemented
MS0191 # 07 Y:2001 07 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $448 $302 Not Implemented
MS0191 # 08 Y:2001 08 2001 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,135 $2,916 Not Implemented
MS0147 # 01 Y:1999 01 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $15,658 $1,110 Implemented