Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

369

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0195 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,161 $264 Implemented
MO0195 # 02 Y:1996 02 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,931 $80 Not Implemented
MO0195 # 01 Y:1996 01 1996 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $19,791 $0 Not Implemented
MO0195 # 08 Y:1996 08 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $589 $0 Implemented
MO0194 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,051 $3,760 Implemented
MO0194 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $945 $1,527 Implemented
MO0194 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,753 $264 Implemented
MO0194 # 04 Y:1996 04 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,976 $0 Implemented
MO0194 # 05 Y:1996 05 1996 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $15,288 $0 Not Implemented
CO0376 # 02 Y:1996 02 1996 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $7,040 $0 Implemented
CO0376 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $518 $470 Implemented
CO0376 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $417 $1,818 Not Implemented
CO0376 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,380 $500 Implemented
CO0376 # 06 Y:1996 06 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,320 $350 Implemented
CO0376 # 07 Y:1996 07 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $650 $2,620 Implemented
CO0376 # 01 Y:1996 01 1996 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,040 $1,000 Not Implemented
UM0064 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,967 $4,130 n/a
UM0060 # 05 Y:1996 05 1996 TREAT AND REUSE RINSE WATERS $1,039 $1,000 Implemented
UM0060 # 04 Y:1996 04 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,807 $2,550 Implemented
MS0069 # 06 Y:1996 06 1996 $10,080 $640 Not Implemented
MS0069 # 05 Y:1996 05 1996 USE POWER DURING OFF-PEAK PERIODS $81,053 $0 Not Implemented
MS0069 # 04 Y:1996 04 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,012 $925 Not Implemented
MS0069 # 03 Y:1996 03 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,360 $7,226 Not Implemented
MS0069 # 02 Y:1996 02 1996 RECOVER WASTE HEAT FROM EQUIPMENT $2,677 $2,740 Not Implemented
UM0064 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $557 $400 n/a