Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 331 | Blast Furnace And Basic Steel Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL2307 # 01 Y:2023 | 01 | 2023 | INSTALL OCCUPANCY SENSORS | $1,100 | $2,693 | Implemented |
UL2307 # 02 Y:2023 | 02 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,654 | $33,973 | Implemented |
UL2307 # 07 Y:2023 | 07 | 2023 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $36,790 | $34,740 | Implemented |
UK1801 # 06 Y:2018 | 06 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $860 | $1,250 | Implemented |
UK1801 # 05 Y:2018 | 05 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,263 | $2,190 | Implemented |
UK1801 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $2,773 | $1,959 | Implemented |
UK1801 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,208 | $48,400 | Implemented |
UK1403 # 03 Y:2014 | 03 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,250 | $0 | Implemented |
UK1403 # 15 Y:2014 | 15 | 2014 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $34,100 | $5,000 | Implemented |
UK1403 # 12 Y:2014 | 12 | 2014 | USE PHOTOCELL CONTROLS | $3,867 | $947 | Implemented |
UK1403 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $50,851 | $9,648 | Implemented |
UK1403 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $132,390 | $479,700 | Implemented |
UK1403 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $69,620 | $7,000 | Implemented |
UK1403 # 04 Y:2014 | 04 | 2014 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $26,100 | $0 | Implemented |
UK1312 # 10 Y:2013 | 10 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $109,909 | $9,000 | Implemented |
UK1312 # 09 Y:2013 | 09 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $815 | $0 | Implemented |
UK1312 # 06 Y:2013 | 06 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,527 | $1,376 | Implemented |
UK1312 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,570 | $504 | Implemented |
UK1312 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,264 | $5,000 | Implemented |
UK1312 # 02 Y:2013 | 02 | 2013 | UPGRADE OBSOLETE EQUIPMENT | $54,717 | $520,000 | Implemented |
UL0238 # 02 Y:2000 | 02 | 2000 | DISCONNECT BALLASTS | $12,291 | $1,236 | Implemented |
TN0386 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $659 | $500 | Implemented |
TN0386 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,407 | $3,860 | Implemented |
TN0386 # 03 Y:1989 | 03 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,664 | $0 | Implemented |
TN0386 # 01 Y:1989 | 01 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,995 | $9,500 | Implemented |