Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsSIC | 331 | Blast Furnace And Basic Steel Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0413 # 07 Y:2016 | 07 | 2016 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,462 | $25,000 | Implemented |
LE0413 # 01 Y:2016 | 01 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,124 | $500 | Implemented |
LE0413 # 02 Y:2016 | 02 | 2016 | INSTALL OCCUPANCY SENSORS | $1,494 | $725 | Implemented |
LE0413 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $973 | $1,000 | Implemented |
LE0413 # 05 Y:2016 | 05 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $482 | $590 | Implemented |
LE0413 # 06 Y:2016 | 06 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,404 | $15,000 | Implemented |
LE0406 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,582 | $1,000 | Implemented |
LE0406 # 03 Y:2015 | 03 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,001 | $300 | Implemented |
LE0406 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,200 | $0 | Implemented |
LE0406 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $6,858 | $8,310 | Implemented |
LE0406 # 07 Y:2015 | 07 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $24,691 | $65,000 | Implemented |
LE0390 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $47,479 | $25,500 | Implemented |
LE0332 # 08 Y:2012 | 08 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,829 | $40 | Implemented |
LE0332 # 07 Y:2012 | 07 | 2012 | DEVELOP STANDARD OPERATING PROCEDURES | $6,689 | $0 | Implemented |
LE0331 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,005 | $1,000 | Implemented |
LE0331 # 07 Y:2012 | 07 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,134 | $2,500 | Implemented |
LE0331 # 05 Y:2012 | 05 | 2012 | REDESIGN PROCESS | $20,100 | $0 | Implemented |
LE0331 # 04 Y:2012 | 04 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $24,579 | $0 | Implemented |
LE0283 # 24 Y:2009 | 24 | 2009 | INSTALL OCCUPANCY SENSORS | $550 | $600 | Implemented |
LE0283 # 23 Y:2009 | 23 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,799 | $32,466 | Implemented |
LE0283 # 12 Y:2009 | 12 | 2009 | COVER OPEN TANKS | $9,339 | $10,000 | Implemented |
LE0283 # 11 Y:2009 | 11 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $18,031 | $30,000 | Implemented |
LE0283 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,658 | $1,672 | Implemented |
LE0283 # 03 Y:2009 | 03 | 2009 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $38,523 | $560 | Implemented |
LE0283 # 02 Y:2009 | 02 | 2009 | REPLACE DC EQUIPMENT WITH AC EQUIPMENT | $46,426 | $38,000 | Implemented |