Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
897
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0877 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,245 | $0 | Implemented |
OK0877 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $652 | $3,540 | Implemented |
OK0877 # 06 Y:2014 | 06 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $52 | $30 | Implemented |
OK0877 # 09 Y:2014 | 09 | 2014 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $2,159 | $1,600 | Implemented |
BS0026 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $339 | $120 | Implemented |
BS0026 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $478 | $15 | Implemented |
BS0026 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,850 | $752 | Implemented |
MZ0111 # 03 Y:2013 | 03 | 2013 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $283 | $680 | Implemented |
MZ0111 # 05 Y:2013 | 05 | 2013 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $7,873 | $900 | Implemented |
UM0420 # 02 Y:2013 | 02 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $3,958 | $500 | Implemented |
UM0420 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,312 | $200 | Implemented |
UM0420 # 08 Y:2013 | 08 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,994 | $1,000 | Implemented |
UM0420 # 09 Y:2013 | 09 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,821 | $1,000 | Implemented |
UD0878 # 01 Y:2013 | 01 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,520 | $0 | Implemented |
UD0878 # 02 Y:2013 | 02 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,314 | $9,180 | Implemented |
UD0878 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,303 | $1,000 | Implemented |
UD0878 # 06 Y:2013 | 06 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,575 | $15,000 | Implemented |
IP0010 # 01 Y:2013 | 01 | 2013 | APPLY FOR INVESTMENT INCENTIVES | $4,545 | $0 | Implemented |
IP0010 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,822 | $0 | Implemented |
IP0010 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $446 | $0 | Implemented |
IP0010 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $1,962 | $107 | Implemented |
IP0010 # 07 Y:2013 | 07 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $571 | $221 | Implemented |
IP0010 # 09 Y:2013 | 09 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,108 | $1,795 | Implemented |
IP0010 # 12 Y:2013 | 12 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,469 | $15,876 | Implemented |
IP0010 # 13 Y:2013 | 13 | 2013 | OPTIMIZE PLANT POWER FACTOR | $2,850 | $8,526 | Implemented |