Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,069
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0331 # 09 Y:2003 | 09 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $34,789 | $29,757 | Not Implemented |
IA0331 # 10 Y:2003 | 10 | 2003 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $8,977 | $10,800 | Not Implemented |
IA0331 # 11 Y:2003 | 11 | 2003 | INSULATE BARE EQUIPMENT | $1,491 | $3,352 | Not Implemented |
IA0331 # 12 Y:2003 | 12 | 2003 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $200,000 | $200,000 | Not Implemented |
IA0331 # 13 Y:2003 | 13 | 2003 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $18,530 | $12,000 | Not Implemented |
IA0331 # 14 Y:2003 | 14 | 2003 | COVER OPEN TANKS | $1,451 | $4,500 | Not Implemented |
IA0331 # 15 Y:2003 | 15 | 2003 | AUTOMATE PAYROLL SYSTEM | $9,200 | $12,500 | Implemented |
MS0230 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $48,240 | $31,484 | Not Implemented |
MS0230 # 02 Y:2003 | 02 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,927 | $50 | Implemented |
MS0230 # 03 Y:2003 | 03 | 2003 | RECYCLE CASTING SAND | $6,972 | $0 | Not Implemented |
MS0230 # 04 Y:2003 | 04 | 2003 | USE PHOTOCELL CONTROLS | $864 | $334 | Not Implemented |
MS0230 # 05 Y:2003 | 05 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $724 | $1,800 | Not Implemented |
MS0230 # 06 Y:2003 | 06 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $514 | $1,080 | Not Implemented |
MS0230 # 07 Y:2003 | 07 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $238 | $62 | Implemented |
MS0230 # 08 Y:2003 | 08 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $233 | $602 | Not Implemented |
MA0538 # 01 Y:2003 | 01 | 2003 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $141,119 | $1,825,320 | Not Implemented |
MA0538 # 02 Y:2003 | 02 | 2003 | IMPROVE COMBUSTION CONTROL CAPABILITY | $33,322 | $76,300 | Not Implemented |
MA0538 # 03 Y:2003 | 03 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $31,418 | $1,200 | Implemented |
MA0538 # 04 Y:2003 | 04 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,650 | $60,800 | Implemented |
MA0538 # 05 Y:2003 | 05 | 2003 | COVER OPEN TANKS | $12,160 | $39,000 | Not Implemented |
MA0538 # 06 Y:2003 | 06 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $10,594 | $44,750 | Not Implemented |
MA0538 # 07 Y:2003 | 07 | 2003 | OPTIMIZE PLANT POWER FACTOR | $10,424 | $31,667 | Not Implemented |
MA0538 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,238 | $85 | Implemented |
GT0759 # 01 Y:2003 | 01 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $5,870 | $3,000 | Implemented |
GT0759 # 02 Y:2003 | 02 | 2003 | INSULATE BARE EQUIPMENT | $770,950 | $340,200 | Not Implemented |