Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
118
matching recommendationsSIC | 3321 | Gray And Ductile Iron Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0824 # 20 Y:2010 | 20 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,372 | $11,000 | Not Implemented |
UD0692 # 01 Y:2004 | 01 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $47,634 | $0 | Not Implemented |
UD0692 # 02 Y:2004 | 02 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $9,960 | $6,000 | Not Implemented |
UD0692 # 03 Y:2004 | 03 | 2004 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,672 | $344 | Not Implemented |
UD0692 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,575 | $325 | Implemented |
UD0692 # 05 Y:2004 | 05 | 2004 | COVER OPEN TANKS | $888 | $3,450 | Implemented |
UD0692 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $570 | $0 | Not Implemented |
UD0692 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $400 | Implemented |
UD0692 # 08 Y:2004 | 08 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $155 | $53 | Not Implemented |
UD0608 # 01 Y:2000 | 01 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $27,415 | $15,000 | Implemented |
UD0608 # 02 Y:2000 | 02 | 2000 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $13,231 | $1,200 | Implemented |
UD0608 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,027 | $6,250 | Implemented |
UD0608 # 04 Y:2000 | 04 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,480 | $14,755 | Implemented |
UD0608 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,156 | $3,500 | Not Implemented |
UD0608 # 06 Y:2000 | 06 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,103 | $0 | Not Implemented |
UD0608 # 07 Y:2000 | 07 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,709 | $4,624 | Not Implemented |
UD0593 # 01 Y:2000 | 01 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $75,117 | $0 | Not Implemented |
UD0593 # 02 Y:2000 | 02 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $42,268 | $45,000 | Implemented |
UD0593 # 03 Y:2000 | 03 | 2000 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $36,834 | $55,945 | Not Implemented |
UD0593 # 04 Y:2000 | 04 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,243 | $6,080 | Implemented |
UD0593 # 05 Y:2000 | 05 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,710 | $0 | Not Implemented |
UD0571 # 01 Y:1999 | 01 | 1999 | RECYCLE CASTING SAND | $227,844 | $135,000 | Implemented |
UD0571 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $67,000 | $24,000 | Not Implemented |
UD0571 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $27,700 | $40,000 | Not Implemented |
UD0571 # 04 Y:1999 | 04 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $21,000 | $64,000 | Implemented |