Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
113
matching recommendationsSIC | 333 | Primary Nonferrous Metals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0468 # 01 Y:2015 | 01 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $3,541 | $0 | Implemented |
SF0468 # 10 Y:2015 | 10 | 2015 | REPLACE BOILER | $9,878 | $51,914 | Implemented |
OR0644 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,865 | $3,865 | Implemented |
OR0644 # 04 Y:2015 | 04 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $37,274 | $20,400 | Implemented |
OR0644 # 03 Y:2015 | 03 | 2015 | ELIMINATE/REDUCE AN OPERATION | $106,634 | $72,750 | Implemented |
UM0435 # 04 Y:2013 | 04 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,000 | $3,000 | Implemented |
UM0435 # 03 Y:2013 | 03 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $966 | $2,500 | Implemented |
UM0435 # 01 Y:2013 | 01 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $4,450 | $4,500 | Implemented |
UM0417 # 05 Y:2012 | 05 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $6,000 | $200 | Implemented |
UM0417 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,780 | $58,125 | Implemented |
OR0592 # 03 Y:2012 | 03 | 2012 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $40,400 | $70,000 | Implemented |
OR0592 # 04 Y:2012 | 04 | 2012 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $15,020 | $0 | Implemented |
MZ0071 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $285 | $610 | Implemented |
MZ0071 # 10 Y:2011 | 10 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,736 | $6,494 | Implemented |
MZ0071 # 09 Y:2011 | 09 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,831 | $0 | Implemented |
MZ0071 # 08 Y:2011 | 08 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $35 | $50 | Implemented |
MZ0071 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,223 | $800 | Implemented |
MZ0071 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,810 | $1,300 | Implemented |
MZ0071 # 04 Y:2011 | 04 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $19,137 | $1,000 | Implemented |
MZ0071 # 03 Y:2011 | 03 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $429 | $0 | Implemented |
MZ0070 # 04 Y:2011 | 04 | 2011 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,769 | $360 | Implemented |
MZ0070 # 03 Y:2011 | 03 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,071 | $1,122 | Implemented |
MZ0070 # 02 Y:2011 | 02 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,693 | $920 | Implemented |
MZ0070 # 01 Y:2011 | 01 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,076 | $800 | Implemented |
MZ0070 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $40,140 | $10,000 | Implemented |