Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
233
matching recommendationsSIC | 3369 | Nonferrous Foundries, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0355 # 08 Y:1999 | 08 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $7,780 | $2,016 | Not Implemented |
MA0392 # 01 Y:1997 | 01 | 1997 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $34,500 | $21,950 | Implemented |
MA0392 # 02 Y:1997 | 02 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $8,500 | $3,000 | Not Implemented |
MA0392 # 03 Y:1997 | 03 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,388 | $6,000 | Not Implemented |
MA0392 # 04 Y:1997 | 04 | 1997 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $320 | $268 | Implemented |
MA0392 # 05 Y:1997 | 05 | 1997 | CONVERT TO AQUEOUS CLEANING | $276 | $759 | Implemented |
WV0111 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $338 | $96 | Not Implemented |
WV0111 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,354 | $27,486 | Implemented |
WV0111 # 03 Y:1997 | 03 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,858 | $720 | Implemented |
WV0111 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,405 | $250 | Not Implemented |
WV0111 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,373 | $100 | Implemented |
WV0111 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $42,260 | $0 | Implemented |
WV0111 # 07 Y:1997 | 07 | 1997 | USE SHAFT TYPE FURNACES FOR PREHEATING INCOMING MATERIAL | $38,225 | $20,000 | Not Implemented |
WV0111 # 08 Y:1997 | 08 | 1997 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $58,339 | $56,250 | Not Implemented |
WV0111 # 09 Y:1997 | 09 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,033 | $2,000 | Implemented |
WV0111 # 10 Y:1997 | 10 | 1997 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,079 | $0 | Implemented |
WV0111 # 11 Y:1997 | 11 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $180 | $0 | Implemented |
WV0111 # 12 Y:1997 | 12 | 1997 | SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS | $1,256 | $2,400 | Implemented |
OR0246 # 01 Y:1995 | 01 | 1995 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $12,000 | $19,000 | Not Implemented |
OR0246 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,521 | $6,281 | Implemented |
OR0246 # 03 Y:1995 | 03 | 1995 | MINIMIZE WATER USAGE | $3,070 | $0 | Implemented |
OR0246 # 04 Y:1995 | 04 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $122,760 | $205,000 | Implemented |
OR0246 # 05 Y:1995 | 05 | 1995 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $2,530 | $6,500 | Implemented |
OR0246 # 06 Y:1995 | 06 | 1995 | OPTIMIZE PLANT POWER FACTOR | $5,000 | $14,000 | Not Implemented |
MA0325 # 01 Y:1995 | 01 | 1995 | COVER OPEN TANKS | $3,618 | $1,883 | Implemented |