Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,047
matching recommendationsSIC | 339 | Miscellaneous Primary Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0077 # 03 Y:2012 | 03 | 2012 | COVER OPEN TANKS | $4,562 | $154 | Not Implemented |
UA0077 # 04 Y:2012 | 04 | 2012 | USE OPTIMUM THICKNESS INSULATION | $880 | $913 | Not Implemented |
UA0077 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $24,553 | $800 | Not Implemented |
UA0077 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,608 | $2,000 | Not Implemented |
UA0077 # 07 Y:2012 | 07 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,398 | $58 | Not Implemented |
UMS006 # 01 Y:2012 | 01 | 2012 | CONVERT TO OXYFUEL BURNERS | $710,000 | $550,000 | Not Implemented |
UMS006 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $105,000 | $210,000 | Not Implemented |
UMS006 # 03 Y:2012 | 03 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $28,000 | $10,000 | Implemented |
UMS006 # 04 Y:2012 | 04 | 2012 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $6,500 | $5,000 | Not Implemented |
UMS006 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $4,800 | $9,000 | Not Implemented |
AM0603 # 01 Y:2012 | 01 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $80,070 | $66,160 | Implemented |
AM0603 # 02 Y:2012 | 02 | 2012 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $30,000 | $2,320 | Implemented |
AM0603 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,750 | $1,000 | Implemented |
AM0603 # 04 Y:2012 | 04 | 2012 | OPTIMIZE PLANT POWER FACTOR | $4,730 | $9,440 | Not Implemented |
AM0603 # 05 Y:2012 | 05 | 2012 | USE PHOTOCELL CONTROLS | $2,890 | $260 | Implemented |
AM0603 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,080 | $1,000 | Implemented |
AM0603 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,040 | $500 | Implemented |
AM0603 # 08 Y:2012 | 08 | 2012 | PAY UTILITY BILLS ON TIME | $1,684 | $0 | Implemented |
AM0603 # 09 Y:2012 | 09 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,655 | $0 | Not Implemented |
AM0603 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,180 | $3,110 | Implemented |
AM0603 # 11 Y:2012 | 11 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $720 | $20 | Implemented |
AM0603 # 12 Y:2012 | 12 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $190 | $0 | Not Implemented |
WV0436 # 01 Y:2011 | 01 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $62,911 | $74,268 | Not Implemented |
WV0436 # 02 Y:2011 | 02 | 2011 | OPTIMIZE PLANT POWER FACTOR | $32,243 | $22,700 | Not Implemented |
WV0436 # 03 Y:2011 | 03 | 2011 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $21,604 | $29,900 | Not Implemented |