Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,274
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0177 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $725 | $466 | Implemented |
MA0400 # 03 Y:1997 | 03 | 1997 | COVER OPEN TANKS | $15,677 | $6,578 | Implemented |
MA0400 # 05 Y:1997 | 05 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $388 | $0 | Implemented |
NC0124 # 01 Y:1997 | 01 | 1997 | AIR CONDITION ONLY SPACE NECESSARY | $9,590 | $3,000 | Implemented |
NC0124 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $790 | $270 | Implemented |
NC0124 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,913 | $6,240 | Implemented |
NC0124 # 08 Y:1997 | 08 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,572 | $2,000 | Implemented |
NC0124 # 10 Y:1997 | 10 | 1997 | IMPLEMENT A MACHINE AND COOLANT SUMP CLEANING PROGRAM TO MINIMIZE COOLANT CONTAMINATION | $7,405 | $0 | Implemented |
NC0124 # 11 Y:1997 | 11 | 1997 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $2,755 | $2,830 | Implemented |
NC0124 # 14 Y:1997 | 14 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $12,000 | $8,500 | Implemented |
NC0124 # 15 Y:1997 | 15 | 1997 | INSTALL MAGAZINES FOR TEMPORARY STORAGE | $92,400 | $35,000 | Implemented |
NC0123 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,987 | $0 | Implemented |
NC0123 # 10 Y:1997 | 10 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $375 | $200 | Implemented |
NC0123 # 11 Y:1997 | 11 | 1997 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $10,775 | $0 | Implemented |
NC0123 # 12 Y:1997 | 12 | 1997 | IMPROVE SPACE COMFORT CONDITIONING | $115,000 | $200,000 | Implemented |
UD0529 # 01 Y:1997 | 01 | 1997 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $4,259 | $0 | Implemented |
UD0529 # 02 Y:1997 | 02 | 1997 | COMBINE UTILITY METERS | $1,939 | $3,357 | Implemented |
UD0529 # 04 Y:1997 | 04 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $551 | $500 | Implemented |
UD0529 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,396 | $200 | Implemented |
BD0095 # 01 Y:1997 | 01 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,163 | $1,500 | Implemented |
BD0095 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,013 | $7,630 | Implemented |
BD0095 # 04 Y:1997 | 04 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,717 | $1,500 | Implemented |
BD0095 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $1,553 | $225 | Implemented |
BD0095 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $699 | $1,201 | Implemented |
BD0094 # 03 Y:1997 | 03 | 1997 | INSULATE BARE EQUIPMENT | $4,842 | $8,668 | Implemented |