Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,436
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0462 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,285 | $0 | Implemented |
SF0462 # 03 Y:2015 | 03 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,475 | $793 | Implemented |
SF0462 # 04 Y:2015 | 04 | 2015 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,104 | $1,941 | Implemented |
SF0462 # 05 Y:2015 | 05 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,415 | $12,500 | Not Implemented |
SF0462 # 06 Y:2015 | 06 | 2015 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $601 | $1,000 | Not Implemented |
SF0462 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $2,234 | $4,284 | Implemented |
SF0462 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,459 | $24,914 | Implemented |
SF0462 # 09 Y:2015 | 09 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,227 | $11,712 | Not Implemented |
SD0488 # 01 Y:2014 | 01 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,838 | $7,262 | Not Implemented |
SD0488 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,362 | $2,700 | Implemented |
SD0488 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,081 | $14,125 | Not Implemented |
SD0488 # 04 Y:2014 | 04 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,681 | $6,350 | Implemented |
SD0488 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,278 | $3,660 | Not Implemented |
SD0488 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,195 | $3,145 | Not Implemented |
SD0484 # 01 Y:2014 | 01 | 2014 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $111,951 | $87,500 | Not Implemented |
SD0484 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,136 | $45,100 | Implemented |
SD0484 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,196 | $1,300 | Implemented |
SD0484 # 04 Y:2014 | 04 | 2014 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $6,896 | $400 | Implemented |
SD0484 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,758 | $300 | Implemented |
SD0484 # 06 Y:2014 | 06 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,388 | $4,600 | Not Implemented |
SD0484 # 07 Y:2014 | 07 | 2014 | USE PHOTOCELL CONTROLS | $1,281 | $3,700 | Implemented |
SF0436 # 01 Y:2013 | 01 | 2013 | COVER OPEN TANKS | $6,314 | $150 | Not Implemented |
SF0436 # 02 Y:2013 | 02 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $438 | $0 | Implemented |
SF0436 # 03 Y:2013 | 03 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $2,488 | $3,272 | Not Implemented |
SF0436 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $864 | $2,751 | Not Implemented |