Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,750
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0469 # 04 Y:2004 | 04 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,460 | $170 | Implemented |
AM0469 # 05 Y:2004 | 05 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $890 | $0 | Not Implemented |
AM0469 # 06 Y:2004 | 06 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $340 | $0 | Implemented |
AM0469 # 07 Y:2004 | 07 | 2004 | USE SYNTHETIC LUBRICANT | $260 | $0 | Not Implemented |
AM0468 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,870 | $14,200 | n/a |
AM0468 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,520 | $800 | Implemented |
AM0468 # 03 Y:2004 | 03 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,510 | $760 | Implemented |
AM0468 # 04 Y:2004 | 04 | 2004 | OPTIMIZE PLANT POWER FACTOR | $1,100 | $4,590 | Not Implemented |
AM0468 # 05 Y:2004 | 05 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $270 | $110 | Implemented |
AM0468 # 06 Y:2004 | 06 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $37,000 | $0 | Implemented |
AM0468 # 07 Y:2004 | 07 | 2004 | PAY UTILITY BILLS ON TIME | $390 | $0 | Implemented |
AM0466 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $4,850 | $6,300 | Implemented |
AM0466 # 02 Y:2004 | 02 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,595 | $6,000 | Not Implemented |
AM0466 # 03 Y:2004 | 03 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,980 | $0 | Implemented |
AM0466 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,810 | $500 | Implemented |
AM0466 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,125 | $1,070 | Not Implemented |
AM0466 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $790 | $215 | Implemented |
AM0466 # 07 Y:2004 | 07 | 2004 | PAY UTILITY BILLS ON TIME | $600 | $0 | Implemented |
AM0466 # 08 Y:2004 | 08 | 2004 | USE SYNTHETIC LUBRICANT | $279 | $0 | Implemented |
AM0462 # 01 Y:2004 | 01 | 2004 | PAY UTILITY BILLS ON TIME | $26,800 | $6,700 | Implemented |
AM0462 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,320 | $2,000 | Implemented |
AM0462 # 03 Y:2004 | 03 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,200 | $1,400 | Implemented |
AM0462 # 04 Y:2004 | 04 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,060 | $0 | Implemented |
AM0462 # 05 Y:2004 | 05 | 2004 | INSTALL SKYLIGHTS | $2,670 | $6,600 | Not Implemented |
AM0462 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,630 | $45 | Not Implemented |