Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
413
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0532 # 02 Y:1999 | 02 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,040 | $20,000 | Implemented |
KU0532 # 01 Y:1999 | 01 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,410 | $17,000 | Not Implemented |
KU0523 # 06 Y:1999 | 06 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $4,740 | $6,300 | Not Implemented |
KU0523 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $740 | $450 | Not Implemented |
KU0523 # 04 Y:1999 | 04 | 1999 | USE SYNTHETIC LUBRICANT | $800 | $1,530 | Not Implemented |
KU0523 # 03 Y:1999 | 03 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,100 | $560 | Not Implemented |
KU0523 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,040 | $2,050 | Not Implemented |
KU0523 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $7,490 | $7,600 | Not Implemented |
KU0522 # 06 Y:1999 | 06 | 1999 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $2,600 | $4,500 | Implemented |
KU0522 # 05 Y:1999 | 05 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $7,710 | $1,100 | Implemented |
KU0522 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $250 | $500 | Not Implemented |
KU0522 # 03 Y:1999 | 03 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $470 | $0 | Implemented |
KU0522 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,840 | $1,410 | Not Implemented |
KU0522 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,170 | $710 | Implemented |
KU0521 # 05 Y:1999 | 05 | 1999 | AUTOMATE FINISHING PROCESS | $68,610 | $109,420 | Implemented |
KU0521 # 04 Y:1999 | 04 | 1999 | USE SYNTHETIC LUBRICANT | $230 | $640 | Implemented |
KU0521 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $270 | Implemented |
KU0521 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $640 | $500 | Implemented |
KU0521 # 01 Y:1999 | 01 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $3,190 | $8,580 | Not Implemented |
KU0512 # 12 Y:1999 | 12 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $220,990 | $233,750 | Not Implemented |
KU0512 # 11 Y:1999 | 11 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $800,000 | $29,240 | Not Implemented |
KU0512 # 10 Y:1999 | 10 | 1999 | CONVERT TO ELECTROSTATIC POWDER COATING | $278,220 | $513,480 | Not Implemented |
KU0512 # 09 Y:1999 | 09 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $550 | $770 | Not Implemented |
KU0512 # 08 Y:1999 | 08 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $990 | $700 | Not Implemented |
KU0512 # 07 Y:1999 | 07 | 1999 | INSULATE BARE EQUIPMENT | $1,520 | $1,030 | Not Implemented |