IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

436

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0187 # 09 Y:2000 09 2000 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $8,686 $25,740 Not Implemented
TN0673 # 01 Y:2000 01 2000 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,075 $2,610 Implemented
TN0673 # 02 Y:2000 02 2000 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $980 $1,075 Not Implemented
TN0673 # 03 Y:2000 03 2000 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $715 $1,820 Not Implemented
TN0673 # 04 Y:2000 04 2000 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $710 $0 Not Implemented
TN0673 # 05 Y:2000 05 2000 USE A RAG RECYCLE SERVICE $240 $0 Not Implemented
TN0673 # 06 Y:2000 06 2000 CONTRACT A WOOD PALLET RECYCLING COMPANY $160 $0 Implemented
NC0156 # 01 Y:1999 01 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $9,453 $15,000 Not Implemented
NC0156 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $27,013 $1,295 Not Implemented
NC0156 # 03 Y:1999 03 1999 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $461,046 $1,000,000 Implemented
NC0156 # 04 Y:1999 04 1999 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $65,000 $80,000 Implemented
NC0156 # 05 Y:1999 05 1999 USE REACTIVE RINSING $2,015 $325 Not Implemented
NC0154 # 01 Y:1998 01 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,913 $15,000 n/a
NC0154 # 02 Y:1998 02 1998 CLOSE OFF UNNEEDED STEAM LINES $2,893 $3,000 n/a
NC0154 # 03 Y:1998 03 1998 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $2,295 $825 n/a
NC0154 # 04 Y:1998 04 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,693 $5,000 n/a
NC0154 # 05 Y:1998 05 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $1,140 $0 n/a
NC0154 # 06 Y:1998 06 1998 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $3,876 $1,500 n/a
NC0154 # 07 Y:1998 07 1998 USE ADSORPTION, ION EXCHANGE TO REMOVE CONTAMINANTS $62,900 $5,500 n/a
NC0154 # 08 Y:1998 08 1998 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $520,000 $0 n/a
NC0146 # 01 Y:1998 01 1998 COVER OPEN TANKS $488 $600 Implemented
NC0146 # 02 Y:1998 02 1998 INSULATE BARE EQUIPMENT $920 $800 Implemented
NC0146 # 03 Y:1998 03 1998 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $409 $1,480 Implemented
NC0146 # 04 Y:1998 04 1998 RECOVER WASTE HEAT FROM EQUIPMENT $178 $200 Implemented
NC0146 # 05 Y:1998 05 1998 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $13,890 $1,500 Implemented