Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
730
matching recommendationsSIC | 343 | Plumbing And Heating, Except Electric |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0008 # 07 Y:2001 | 07 | 2001 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $105,300 | $1,212 | n/a |
NC0212 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,685 | $25 | Implemented |
NC0212 # 02 Y:2001 | 02 | 2001 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $5,740 | $5,000 | Not Implemented |
NC0212 # 03 Y:2001 | 03 | 2001 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $2,554 | $11,000 | Not Implemented |
NC0212 # 04 Y:2001 | 04 | 2001 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,456 | $800 | Not Implemented |
NC0212 # 05 Y:2001 | 05 | 2001 | USE OPTIMUM THICKNESS INSULATION | $3,300 | $5,000 | Not Implemented |
NC0212 # 06 Y:2001 | 06 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $392 | $120 | Not Implemented |
NC0212 # 07 Y:2001 | 07 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,001 | $1,589 | Not Implemented |
NC0212 # 08 Y:2001 | 08 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,950 | $8,846 | Not Implemented |
NC0212 # 09 Y:2001 | 09 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,215 | $18,300 | Not Implemented |
NC0212 # 10 Y:2001 | 10 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,136 | $2,093 | Not Implemented |
NC0212 # 11 Y:2001 | 11 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $825 | $0 | Not Implemented |
NV0166 # 01 Y:2000 | 01 | 2000 | AIR CONDITION ONLY SPACE NECESSARY | $32,352 | $17,000 | n/a |
NV0166 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $321 | $255 | n/a |
NV0166 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $180 | $194 | n/a |
NV0166 # 04 Y:2000 | 04 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $81 | $0 | n/a |
NV0166 # 05 Y:2000 | 05 | 2000 | AUTOMATE FINISHING PROCESS | $195,000 | $3,465 | n/a |
ND0354 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $355 | $240 | Implemented |
ND0354 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $415 | $660 | Implemented |
ND0354 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,533 | $14,644 | Implemented |
ND0354 # 04 Y:2000 | 04 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,145 | $2,970 | Not Implemented |
ND0354 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,506 | $300 | Implemented |
ND0354 # 06 Y:2000 | 06 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $8,446 | $27,572 | Implemented |
ND0354 # 07 Y:2000 | 07 | 2000 | MINIMIZE WATER USAGE | $2,685 | $6,840 | Implemented |
ND0354 # 08 Y:2000 | 08 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,731 | $0 | Implemented |