Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
718
matching recommendationsSIC | 3462 | Iron And Steel Forgings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0216 # 08 Y:1999 | 08 | 1999 | $25,245 | $22,970 | Not Implemented | |
OK0562 # 01 Y:1998 | 01 | 1998 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $14,801 | $1,936 | Implemented |
OK0562 # 02 Y:1998 | 02 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,344 | $1,516 | Not Implemented |
OK0562 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $850 | $110 | Implemented |
OK0562 # 04 Y:1998 | 04 | 1998 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $526 | $242 | Not Implemented |
OK0562 # 05 Y:1998 | 05 | 1998 | INSTALL OCCUPANCY SENSORS | $360 | $532 | Implemented |
OK0562 # 06 Y:1998 | 06 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $7,243 | $0 | Not Implemented |
OK0562 # 07 Y:1998 | 07 | 1998 | $7,200 | $288 | Implemented | |
OK0562 # 08 Y:1998 | 08 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,160 | $0 | Implemented |
OK0562 # 09 Y:1998 | 09 | 1998 | METER WASTE WATER | $233 | $0 | Implemented |
TN0641 # 01 Y:1998 | 01 | 1998 | $462,700 | $440,300 | Not Implemented | |
TN0641 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,810 | $5,000 | Implemented |
TN0641 # 03 Y:1998 | 03 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $3,560 | $2,500 | Implemented |
TN0641 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,130 | $980 | Implemented |
TN0641 # 05 Y:1998 | 05 | 1998 | USE OPTIMUM THICKNESS INSULATION | $240 | $550 | Not Implemented |
TN0641 # 06 Y:1998 | 06 | 1998 | USE A RAG RECYCLE SERVICE | $140 | $0 | Not Implemented |
AM0328 # 01 Y:1998 | 01 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $44,420 | $0 | Not Implemented |
AM0328 # 02 Y:1998 | 02 | 1998 | METER WASTE WATER | $23,760 | $27,000 | Not Implemented |
AM0328 # 03 Y:1998 | 03 | 1998 | OPTIMIZE PLANT POWER FACTOR | $11,750 | $0 | Implemented |
AM0328 # 04 Y:1998 | 04 | 1998 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,940 | $3,680 | Not Implemented |
AM0328 # 05 Y:1998 | 05 | 1998 | USE SYNTHETIC LUBRICANT | $1,635 | $0 | Not Implemented |
AM0328 # 06 Y:1998 | 06 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $830 | $0 | Not Implemented |
AM0328 # 07 Y:1998 | 07 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $500 | $500 | Implemented |
UD0542 # 01 Y:1998 | 01 | 1998 | $183,600 | $0 | Implemented | |
UD0542 # 02 Y:1998 | 02 | 1998 | RECOVER METALS FROM CASTING SAND | $21,000 | $4,800 | Not Implemented |