Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
460
matching recommendationsSIC | 3469 | Metal Stampings, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0489 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,622 | $6,539 | Implemented |
WV0489 # 05 Y:2014 | 05 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,585 | $0 | Implemented |
WV0489 # 07 Y:2014 | 07 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,213 | $2,425 | Implemented |
WV0489 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,258 | $271 | Implemented |
SU0341 # 05 Y:2013 | 05 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $626 | $137 | Implemented |
SU0341 # 03 Y:2013 | 03 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $299 | $0 | Implemented |
SU0341 # 02 Y:2013 | 02 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $314 | $0 | Implemented |
SU0341 # 01 Y:2013 | 01 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $357 | $0 | Implemented |
SD0464 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,895 | $27,250 | Implemented |
WM0016 # 06 Y:2012 | 06 | 2012 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,004 | $0 | Implemented |
WM0016 # 03 Y:2012 | 03 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,517 | $0 | Implemented |
UM0415 # 05 Y:2012 | 05 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $23,600 | $1,000 | Implemented |
UM0415 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $822 | $875 | Implemented |
MZ0096 # 11 Y:2012 | 11 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $467 | $480 | Implemented |
MZ0096 # 10 Y:2012 | 10 | 2012 | INSTALL OCCUPANCY SENSORS | $455 | $480 | Implemented |
MZ0096 # 09 Y:2012 | 09 | 2012 | USE PHOTOCELL CONTROLS | $507 | $560 | Implemented |
MZ0096 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $896 | $221 | Implemented |
MZ0096 # 07 Y:2012 | 07 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,395 | $5,400 | Implemented |
MZ0096 # 05 Y:2012 | 05 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $11,800 | $22,100 | Implemented |
MZ0096 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,732 | $29,201 | Implemented |
MZ0096 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $57,095 | $67,348 | Implemented |
UD0858 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,006 | $500 | Implemented |
UD0858 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $1,000 | Implemented |
BD0403 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,988 | $5,268 | Implemented |
BD0403 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,011 | $150 | Implemented |